13
Nagra –
MPS
Starting the MPS using the trigger input
REM
On the
R
position, you can start the MPS using
the REM (for REMote) input.
Please note that both the tip and the sleeve of
the 1/8” Jack should be connected to the ground.
Signal on the ring
MPS
Connected to the ground
Off
Open or connected to max 12 V rms
On
Note, in this case, in the ON position, the MPS does not run on battery. If you
wish to use the battery, you need to turn the main selector to
BAT
.
Whenever you connect a jack on the REM connector, it will override the IR remote
control.
Using the trigger output
AMP
See the following picture for cabling of the
1/8” jack.
MPS
Tip and ring
AMP On
Connected
AMP Off
Open
The
AMP
will be activated at the end of the powering sequence, to avoid any
clicks that sometimes occur at start-up. When powering down, the amplifier will
be turn off first.
You can of course connect any other compatible equipment, not only amplifiers.
Case cleaning
Clean the MPS casing using a soft, non-fluffy, slightly damp cloth. Do not use any
cleaning products which could have a corrosive effect.