10
NAC 282
11.6 Mute and Mono
Mute and mono functions can be controlled independently for
source and record signals via the buttons to the left of the two
banks of source and record selection buttons. Mute silences the
output signal, while mono sums the left and right channels.
11.7 Display
The NAC 282 front panel button display can be switched off
by pressing the remote handset (in preamplifier mode)
disp
function. Any subsequent handset or front panel operation will
temporarily restore the display. A second operation of the
disp
function will permanently restore the display.
11.8 Switch-on
After switch-on, via the NAPSC and power supply, or power
amplifier,
power
button, the NAC 282 will remain muted for 30
seconds while control systems and circuits stabilise. The source
side will then un-mute automatically leaving the record side
muted (and its circuits unpowered).
Note:
A flashing mute indicator after switch-on indicates that the
preamplfier power supply or link plugs are incorrectly connected.
11.9 Remote Control
The
NARCOM
remote handset supplied with the NAC 282
duplicates all configuration and control functions. See Section
24 for more information. The
Flash
and
iCom
handset will
also control the NAC 252. See Sections 23 and 25 for more
information.
11.10 Defaults
To restore all programmable settings to the factory defaults press
and hold the remote handset
disp
key while the preamplifier is
in program mode. The preamplifier will exit from program mode
following this operation.
12.1 NAC 282 Front
volume
balance
mute
mono
source
bank
record
bank
to power
amplifier
with internal
power supply
12.2 NAC 282 Rear
in 1
cd
in 2
tuner
in 3
tape
in 4
av
signal
ground
in 6 (alternative)
cd/RCA Phono
ch1
ch2
aux 2/RCA Phono
ch1
ch2
RS232
interface
RC5 in
ch1
-ve
nc
nc
ch2
Inputs 1, 2 & 6
ch1
-ve
ch1
(out)
ch2
(out)
ch2
Inputs 3, 4 & 5
+ve
-ve
+ve
ch1
+ve
ch2
Input 6
(alternative)
in 5
aux 1
in 6
aux 2
Note:
The NAC 282 AUX 2 input is provided with two sockets. The
lower socket, fitted on delivery with a blanking cover, is intended for
use with a Stageline or Prefix RCA Phono stage and incorporates
an appropriate DC power supply. The two sockets must not be used
simultaneously.
Note:
The RS232/comms interface is an optional upgrade. It can
be specified at time of order or fitted retrospectively. Contact your
local representative or Naim Audio directly for further information.
to NAPSC
power supply/output option sockets
with link and blanking plugs fitted
source and record
selection
Summary of Contents for Amplifiers
Page 39: ...37...