25
7. If you are finished setting parameters, turn the Power Switch off.
▲Setting Air Input monitoring override
・The system can be set to operate without cooling air. Maximum speed is 25,000min
-1
when not using
cooling air.
Note : It is not recommended to use the system in this manner for general machining.
This setting is only for light cutting and not for use with coolants.
Procedure)1. Push the Start Switch
2. is displayed. This indicates that air must be supplied to operate the system.
3. Push the Start Switch
4. is displayed. The system can be cofigured to operate without cooling air,
maximum speed is 25,000min
-1
.
5. Push the Error Reset Switch to send the settings to memory will be displayed
depending on the parameter being set.
6. If you desire to set other parameters push the Motor Speed Adjustment Switch to select
the parameter to be set.
7. If you are finished setting parameters, turn the Power Switch off.
〜
▲Confirmation of the Parameter Settings
・Allows user to check the settings of the above parameters
Procedure)1. Push the Start Switch
2. Display oscillates between and the setting for or
3. Push the Start Switch
4. Display oscillates between and the setting for or
5. Push the Start Switch
6. Display oscillates between and the setting for or setting motor
speed (For example, display 30 for 30,000min
-1
(rpm)
)
7. Push the Start Switch
8. Display oscillates between and the setting for or Max. motor speed.