59
English
①
E
3000
CONTROLLER
②
Control Panel
Refer to P
60
"
9
-
2
Control Panel Details
"
section.
③
Input / Output Connector A
Input / Output Connector A is for automatic control and monitoring of motor / spindle system. Refer to P
69
"
16
–
1
(
1
) Details of External Input / Output Connector A Signal
"
section.
Attach the provided Connector Cover A for safety and dust proofing, when not using Input / Output
connector A.
④
Input / Output Connector B
Connector for automatic monitoring of emergency conditions.
Refer to P
75
"
16
–
2
(
1
) Details of External Input / Output Connector B Signal
"
section.
Attach the provided Connector Cover B for safety and dust proofing, when not using Input / Output
connector B.
⑤
Serial I / F Connector
Serial I / F Connector is for the SELECTOR for Communication Cable. Refer to P
43
"
12
-
2
Connection of
Communication Cable
"
section of the E
3000
SELECTOR Operation Manual.
Attach the provided Serial I / F Connector Cover for safety and dust proofing when not using Serial I / F
Connector.
⑥
Motor Connector
Connect the Motor Cord Plug of the motor spindle. Refer to P64
"
13. MOTOR CORD CONNECTION
"
section.
⑦
Air Input Joint
Supply clean, dry, regulated air for motor cooling. Regulate air to between
0
.
25
-
0
.
3
MPa (
36
.
3
-
43
.
5
psi).
Max. Air Consumption is
30
N
ℓ
/min. Air must be supplied to operate the system at maximum rpm. Refer to
P
65
"
14
. AIR HOSE CONNECTION
"
section.
⑧
Air Output Joint
Connect Air Hose to supply clean, dry, regulated air for motor and spindle cooling and purging. Refer to P65
"
14. AIR HOSE CONNECTION
"
section.
⑨
Main Power Switch
ON / OFF main power source. The designation " I " Indicates ON. The designation " O " Indicates OFF.
⑩
Main Power Inlet with Power Supply Fuses
Insert the Power Cord. Refer to P64
"
12. POWER CORD CONNECTION
"
section.
Two fuses (T1.6AL (250V)) have beeninstalled. Make sure the properly rated and type of fuses are used when
replacements are necessary. When replacing fuse, refer to P61
"
10
. REPLACING FUSES
"
section.
CAUTION
Do not connect any device other than E3000 CONTROLLER to the Serial I / F Connector of the
CONTROLLER, as this will cause damage to the CONTROLLER.
CAUTION
If the air pressure is too low the E3000 CONTROLLER will not operate.