76
Pin
No.
Code
Function
Input /
Output
Description
4
SAFE-
2
A
Safety Relay
Contact
2
A
Output
Pin No.
4
and Pin
No.
12
continuity
' ON (Closed) '
Safety Relay is OFF
When there is continuity between Pin
No.
4
and Pin No.
12
are ' ON (Closed) '
Safety Relay is OFF (System Stopped), no
continuity Safety Relay is ' OFF (Open) '
Normal Operation.
5
AUTO +
Control Mode
A U T O S i g n a l
(+)
Output
Control Mode
AUTO Pin No.
5
and Pin No.
13
are
' ON (Closed) '
When Control Mode AUTO is being used,
this Pin No.
5
and Pin No.
13
are ' ON
(Closed) '.
6
PWON +
CONTROLLER
Power Source
Monitor (+)
Output
' ON (Closed) ' :
Main Power Supply
is connected ' OFF
(Open) ' : Main
Power Supply is
disconnected
If the Main Power Switch
⑨
is ON, Pin No.
6
and Pin No.
14
are ' ON (Closed) '.
7
Not Used
―
―
―
*Note : Never use pin labeled not used.
8
Not Used
―
―
―
*Note : Never use pin labeled not used.
9
EMG-INB
Emergency
Stop B
Input
External Power
Source input
for Emergency
Stop Signal or
Emergency Stop
Signal ' OFF (Open) '
External Power Source input for Emergency
Stop Signal or Emergency Stop Signal.
Normal Operation ' ON (Closed) ', Emergency
' OFF (Open) '.
When using the Emergency Stop Signal, set
parameter
. (Refer to P
92
"
18
-
4
Selection of Emergency Stop Function"
section.)
10
MT-CNB
Motor Connect
Contact B
Output
Continuity, ' OFF
(Open) ', between
Pin No. 2 and Pin
No. 10 the motor is
connected.
When there is continuity, OFF, between Pin
No. 2 and Pin 10 are ' OFF (Open) ', the
selected motor is connected, if no continuity
the motor is disconnected or the motor cord
is broken.
11
SAFE-
1
B
Safety Relay
Contact
1
B
Output
Pin No.
3
and Pin
No.
11
continuity
' ON (Closed) '
Safety Relay is OFF
When there is continuity between Pin
No.
3
and Pin No.
11
are ' ON (Closed) '
Safety Relay is OFF (System Stopped), no
continuity Safety Relay is ' OFF (Open) '
Normal Operation.
12
SAFE-2B
Safety Relay
Contact
2
B
Output
Pin No.
4
and Pin
No.
12
continuity
' ON (Closed) '
Safety Relay is OFF
When there is continuity between Pin No.
4
and Pin No.
12
are ' ON (Closed) ' the
Safety Relay is OFF (System Stopped). If
there is no continuity Safety Relay is ' OFF
(Open) ' Normal Operation.
13
AUTO -
Control Mode
AUTO Signal (-)
Output
Control Mode
AUTO Pin No.
5
and Pin No.
13
are
' ON (Closed) '
When Control Mode AUTO is being used, this
Pin No.
5
and Pin No.
13
are ' ON (Closed) '.