84
18 - 3 Contents of Parameters
CAUTION
The operating parameters can be preset depending on the application requirements.
The operating parameter presets ( " Setting of Error Output Mode ", " Setting AUTO mode
for Motor Speed Control ", " Setting Fixed Motor Speed ", " Setting Maximum Motor Speed ",
" Selection of External Speed Control Mode ", " Selection of External Motor Start Signal Control
Mode ", " Selection of Air Input Monitoring Override ", " Selection of Motor Speed Control Voltage
/ DC+10V Signal Method ", " Selection of Emergency Stop Function " and, " Error History " ) are
retained in non - volatile memory and will be maintained even if power is disconnected.
Please operate only after con
¿
rming contents of parameter settings.
CAUTION
If you set the rotation speed higher than the rotation speed set at
,
rotation speed will be set
according to
.
The following parameters can be set.
①
Setting of Error Output Mode
・
Selection of the error output mode is on " Error (Pin No.
8
: ERR) " of Input / Output Connector A
③
.
・
When an error occurs the output can be select to ' ON (Closed) ' or ' OFF (Open) '.
・
Signals can be output according to the required machine control logic of the system.
Table.
10
Parameter
Set Contents
Error Occurred : Signal is ' OFF (Open) '.
Error Occurred : Signal is ' ON (Closed) '.
Table.
12
Parameter
Set Contents
Fixed Motor Speed is enabled.
Fixed Motor Speed is not enabled.
Table.
11
Parameter
Set Contents
Set the Motor Rotation Speed by External Command Signal
through External Input / Output Connector A
③
.
Set the Motor Rotation Speed by Motor Speed Adjustment
Button (SPEED
,
)
⑬
via the Control Panel
②
.
②
Setting AUTO Mode for Motor Speed Control
・
Allows the setting of the manner in which Motor speed can be controlled when the system is being used
in the Controls' AUTO MODE (External Command Signal Control).
・
This parameter selects between speed control with the Motor Speed Adjustment Button (SPEED
,
)
⑬
of the Control Panel
②
or by External Command Signal through Input / Output Connector A
③
.
③
Setting Fixed Motor Speed
・
Allows the Motor speed to be
¿
xed.
・
Proactively prevents inadvertent change in speed.
・
The Fixed Motor Speed can set by Control Mode MANUAL or AUTO
.