Selection of External Motor Start Signal Control Mode
・
When in Auto Control Mode, the Motor Start Signal can be used for either forward or reverse direction
by commanding a Direction Signal and a Start Signal. When set, the rotation direction is controlled by "
Rotating Direction Setting (Pin No.
2
: DIR_IN) ", ' OFF (Open) ' : FWD, ' ON (Closed) ' : REV and the Start
Signal is controlled by " Rotate Command (Pin No.
14
: START) ".
・
When
is set to
FWD. rotation is controlled by " Rotate Command (Pin No.
14
: START) " and REV.
rotation is controlled by " Rotating Direction Setting (Pin No.
2
: DIR_IN) ".
Table.
16
Parameter
Set Contents
Motor startup and rotating direction is not commanded by signal.
The startup motor with FWD. rotation or the startup motor with REV.
rotation.
⑦
Selection of Air Input Monitoring Override
Table.
17
Parameter
Set Contents
Air pressure is supplied.
Air pressure is not supplied.
⑧
Selection of Motor Speed Control Voltage / DC+
10
V Signal Method
・
Select the Motor Speed Control Voltage Signal and characteristics of the rotational speed according to the
motor.
・
If parameter
is set to
, the motor characteristics will be set to the motors maximum rotation
speed (
60
,
000
min
-
1
(rpm)) .
・
If parameter
is set to
, the characteristics will be set to the motors maximum rotation speed
(
80
,
000
min
-
1
(rpm)) .
・
The Fig.
43
are Characteristics of the VR and rotation speed by parameter
set to
. The Fig.
44
are Characteristics of the VR and rotation speed by parameter
set to
.
CAUTION
・
When using without supplying cooling air as recommended, do not spray coolant directly on the
spindle body.
・
Motor start is possible without supplying cooling air, however maximum motor speed is limit to
30,000min
-1
(rpm).
CAUTION
When using the Motor Speed Control Voltage Signal and the maximum motor speed is 80,000min
-1
(rpm), it is necessary to set parameter
to
when Control Mode is AUTO.