88
⑨
Selection of Emergency Stop Function
・
The Emergency Stop Function can be enabled or disabled.
・
When " Emergency Stop A (Pin No.
1
: EMG - INA) " and " Emergency Stop B (Pin No.
9
: EMG - INB) "
of the External Input / Output Connector B
④
's input signal are set to ' OFF (Open) ', Safety Relay will
activate and block the Motor Power Line and make an emergency stop.
Normally, " Emergency Stop A (Pin No.
1
: EMG - INA) " and " Emergency Stop B (Pin No.
9
: EMG - INB) "
input signal need to be set to ' ON (Closed) '.
・
Allows the establishment of a safe machine operating system.
Table.
19
Parameter
Set Contents
Emergency Stop Function is deactivated.
Emergency Stop Function is activated.
⑩
Error History
・
The Error History, which records previous error codes can be con
¿
rmed by the Error Code displayed on
the digital Speed Indicator
⑪
.
・
Records Error Codes for viewing when machines are being run unattended.
・
In case there is no Error History,
will be displayed on the Digital Speed Indicator
⑪
.
・
The last Error Code recorded will be
and the oldest will be
The Error code is displayed on the
Digital Speed Indicator
⑪
.
・
The Error History cannot be erased or deleted.
・
If Error History contains more than
¿
ve errors, oldest Error History, H
5
will be deleted.
⑪
Con
¿
rmation of Parameter Setting
・
This mode allows the user to check the settings of parameters
-
. The parameter
can not
be checked.
18 - 4 Setting procedures
①
Setting of Error Output Mode
Procedure
1
. Push the START / STOP Button (START / STOP)
⑭
.
2
.
is displayed. This indicates that when an error occurs, the output will be ' OFF (Open) '.
3
. Push the START / STOP Button (START / STOP)
⑭
.
4
.
is displayed. This indicates that when an error occurs, the output will be ' ON (Closed) '.
5
. You can cycle through the choices by pushing the START / STOP Button (START / STOP)
⑭
.
6
. Push the Error Reset Button (RESET)
⑱
to send the settings to memory,
will be displayed.
7
. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
,
)
⑬
to select the parameter that needs to be set.
8
. When you are
¿
nished setting parameters, press the Error Reset Button (RESET)
⑱
then turn the
Main Power Switch
⑨
is OFF.
CAUTION
If the Error Output Mode has been changed from the default setting, that setting will be displayed
the next time you enter Parameter Setting Mode.