91
English
⑥
Selection of External Motor Start Signal Control Mode
Procedure
1
. Push the START / STOP Button (START / STOP)
⑭
.
2
.
is displayed. This indicates that motor startup and setting the rotation direction can not
performed simultaneously.
3
. Push the START / STOP Button (START / STOP)
⑭
.
4
.
is displayed. This setting is right hand rotation with motor startup by " Rotation Command (Pin
No.
14
: START) " or left hand rotation with motor startup by " Rotating Direction Setting (Pin No.
2
: DIR_IN) " can be set.
5
. You can cycle through the choices by pushing the START / STOP Button (START / STOP)
⑭
.
6
. Push the Error Reset Button (RESET)
⑱
while displayed on
to store settings.
7
. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
,
)
⑬
to select the parameter that needs to be set.
8
. When you are
¿
nished setting parameters, press the Error Reset Button (RESET)
⑱
, then turn
the Main Power Switch
⑨
is OFF.
⑦
Selection of Air input Monitoring Override
Procedure
1
. Push the START / STOP Button (START / STOP)
⑭
.
2
.
is displayed. This indicates that supplying cooling air into the motor spindle and motor speed
will perform normally at start - up.
3
. Push the START / STOP Button (START / STOP)
⑭
.
4
.
is displayed. This indicates that without supplying cooling air, motor startup is possible with
limited speed.
5
. You can cycle through the choices by pushing the START / STOP Button (START / STOP)
⑭
.
6
. Push the Error Reset Button (RESET)
⑱
while displayed on
to store the setting.
7
. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
,
)
⑬
to select the parameter that needs to be set.
8
. When you are
¿
nished setting parameters, press the Error Reset Button (RESET)
⑱
, then turn
the Main Power Switch
⑨
is OFF.
⑧
Selection of Motor Speed Control Voltage / DC+
10
V Signal Method
Procedure
1
. Push the START / STOP Button (START / STOP)
⑭
.
2
.
is displayed. This indicates that the motor characteristics will be maximum motor rotation
speed (
60
,
000
min
-
1
(rpm)).
3
. Push the START / STOP Button (START / STOP)
⑭
.
4
.
is displayed. This indicates that the motor characteristics will be maximum motor rotation
speed (
80
,
000
min
-
1
(rpm)).
5
. You can cycle through the choices by pushing the START / STOP Button (START / STOP)
⑭
.
6
. Push the Error Reset Button (RESET)
⑱
to send the settings to memory,
will be displayed.
7
. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
,
)
⑬
to select the parameter that needs to be set.
8
. When you are
¿
nished setting parameters, press the Error Reset Button (RESET)
⑱
and turn the
Main Power Switch
⑨
is OFF.