93
English
20
. Push the Error Reset Button (RESET)
⑱
and
will be displayed.
21
. If you desire to set other parameters, push the Motor Speed Adjustment Button (SPEED
,
)
⑬
to select the parameter that needs to be set.
22
. When you are
¿
nished setting parameters, press the Error Reset Button (RESET)
⑱
, then turn
the Main Power Switch
⑨
is OFF.
19
. BREAK IN PROCEDURE
During transportation, storage or installation the grease inside the bearings will settle. If the spindle is
suddenly run at high - speed, the lack of evenly distributed grease will cuse excessive heat leading to bearing
damage.
After installation, repair, initial operation, or long periods of non operation please follow the break - in
procedure.
Please refer to the " BREAK IN PROCEDURE " in Operation Manual of the Motor / Spindle.
20
. TROUBLESHOOTING
If a problem or concern occurs, please check the following prior to consulting your dealer.
Trouble
Cause
Inspection / Corrective Active
Motor does not run.
Power is not supplied.
・
M a k e s u r e t o t u r n O N t h e M a i n
Power Switch
⑨
on the front of the
CONTROLLER.
・
Insert the power cord Plug correctly into
the Main Power Inlet with Power Supply
Fuses
⑩
of the CONTROLLER.
・
Check if a fuse is blown.
Motor Cord Plug is not connected to the
Motor, CONTROLLER or SELECTOR.
Connect the Motor Cord plug correctly to the
Motor and CONTROLLER or SELECTOR.
Incompatible motor or motor spindle is
connected to the CONTROLLER. (The
Error Code " EL " is displayed on the
Digital Speed Indicator
⑪
.)
Connect the connectable brushless
motor or brushless motor spindle to
the CONTROLLER after released the
Error Code " EL " (Refer to P
56
,
57
"
7
. SYSTEM CHART Fig.
3
,
4
and
5
"
section).
Control Button (CTRL)
⑯
is set to Manual
mode but trying to start with an External
Command Signal through External Input /
Output Connector A
③
.
Start with the START / STOP Button
(START / STOP)
⑭
, or set the Control
Button (CTLR)
⑯
on the Control Panel
②
to Auto mode.
Control Button (CTRL)
⑯
is set to Auto
mode but trying to manually start with the
START / STOP Button (START / STOP)
⑭
on the Control Panel
②
.
S t a r t w i t h a n E x t e r n a l C o m m a n d
Signal or set the Control Button
⑯
on
the Control Panel
②
to Manual mode.
( When Start with an External Command
Signal, refer to P
71
"
16
-
1
(
1
) Details of
External Input / Output Connector A
③
Signal Table.
5
Pin No.
14
" )
When started the
motor, " E.E " is
displayed and motor
does not rotate.
Emergency Stop Signal is ' OFF (Open) '. Check the setting of parameter
.
(Refer to P
92
"
18
-
4
⑨
Selection
of Emergency Stop Function " section.)