26
Regulator Knob
Adjusting Dome
ON / OFF Valve
To Air Compressor
Connection Hose
Connector for Air Hose
Primary Joint
φ
6 One - Touch
Joint
Filter Joint
Silencer
Supply Air /
Oil Hose
Secondary Joint
①
②
Oil Filler Cap
・
Make sure operation air pressure is less than 1.0MPa (145psi) before connecting the
input supply connection hose and air / oil supply hose. If operation air pressure is
exceeds 1.0MPa (145psi), injury to the operator may occur by accidental disconnection
before or during use.
・
Before use, carefully read " Air Line Kit Operation Manuals " regarding the correct
connection, operation and cautions when using the Air Line Kit.
CAUTIONS IN USING AIR LINE KIT
Fig. 7 Connection of Air Line Kit " AL - M1202 (Sold Separately) "
BREAK-IN PROCEDURE
10.
During transportation, storage or installation, the oil inside the bearings may settle. If the Air Turbine
Spindle is suddenly run at high-pressure, the bearings may not have sufficient lubrication, causing
excessive heat that will cause bearing damage.
After installation, repair, initial operation, or long periods of non operation, please carry out break-in as
follow. Slowly supply the air pressure to the Air Turbine Spindle over a period of 10 minutes, increasing
the supply air pressure until working pressure is reached.
OM-K0679_PLANET600_(A5x)_EN_170710発注先変更準備(住所変更).indd 26
2017/07/18 13:55:35