9602-A QUICK START GUIDE
Support Phone#: 571-833-2169
Support@Nalresearch.com
451-92750-004A
2023-03-31
2
DEVICE DESCRIPTION (Continued)
Power/Data Cable:
NAL Research recommends the HRC-24-12 Data/Power
Cable Assembly.
POWER ON DEVICE
The 9602-LP accepts 3.6 VDC to +5.3 VDC input through pin #1 or +6.0 VDC to +32
VDC input through pin #9. The 9602-A ships with hardware set for +6.0 VDC to +32 VDC input.
1. Ensure the device has a clear view of the sky.
2. Supply the appropriate DC power to the 9602-LP via a data/power cable.
a) Connect external power input (+6.0 VDC to +32 VDC – Factory default) to Pin #9 on the multi-interface
connector.
b) Connect external power input (GND) to Pin#2.
•
The 9602-LP defaults to “Tracking” mode and begins tracking.
•
The device automatically powers up when external power is applied. This can be
changed via configuration.
•
The cable to the 9602-LP should be as short as possible to prevent significant voltage drop, which can cause
the 9602-LP to malfunction during an SBD session.
HRC-24-12
Data/Power Cable
CHANGE VOLTAGE INPUT TO +3.6 VDC TO +5.3 VDC
IMPORTANT
Power must be disconnected before resetting the jumper.
1. Remove the modem’s top plate to find the jumper.
2. Set the red jumper onto the middle and top pins. NOTE: To reset the input voltage range back to +6.0 VDC to +32 VDC,
set the red jumper onto the middle and bottom pins.