9602-LP User Guide Version A
Document Number: 451-92750-001A
19 of 61
reset) into the active operating profile using the AT&Fn command. The active operating
profile reverts back to the user-defined operating profile designated under the AT&Yn
command at power reset. Similarly, the active operating profile can be soft reset with either
one of the two user-defined operating profiles during power up with the ATZn command.
Again, the active operating profile reverts back to the user-defined operating profile
designated under the AT&Yn command at power reset.
Figure 7: Different Operating Modes of the 9602-LP
3.1.2.1
N
ORMAL
T
RACKING
M
ODE
Normal Tracking is the mode when the 9602-LP is configured to turn on with the
AT^START1 command or after transitioning from Command mode to Tracking mode with
the AT^TRK command. Normal Tracking provides a wide range of unique settings, as shown
. Each setting can be tailored to meet specific applications. For example, the
9602-LP can be preprogrammed to transmit reports at fixed intervals, to transmit reports
triggered by the internal motion sensor, to transmit reports triggered by the Emergency
switch, or to transmit reports triggered by external devices. The “Callable (No)” option is
implemented when lowest power consumption is required because of limited battery
capacity, or “Same Place Skip Reports” is chosen so that the 9602-LP does not repeatedly
send the same location information back to a command center.
Turn on the
9602-LP
Emergency
Tracking
Emergency button
pressed
or S0 set to Hi/Lo
Hold Emergency
button for 3 sec. to
go to Normal
Tracking or
Command Mode
Normal Tracking
(
See
AT^START1
or AT^TRK
Enter +++ to
switch back to
Command Mode
Test Tracking
S1 set to Hi/Low
Set S1 to Hi/Lo
to go back to
Normal Tracking
Command Mode:
Input tracking parameters
9602-LP as modem with GPS
AT^START0
(Factory Setting)
Enter AT^TRK to begin
Normal Tracking