4.
Click Send. The message “Update Made” is displayed.
After the default Crypto Officer Password has been changed and the encryption and
decryption keys have been set, encryption properties can be modified via the
Change
Encryption Settings
window using the current Crypto Officer Password.
3.3
M
ISCELLANEOUS
S
ETTINGS
The
Miscellaneous
tab has four settings:
Remote Update Password, Identifier in Reports,
Startup Information
, and
Initial Power State
.
Figure 14: Configuration Settings Window: Miscellaneous Options
Use Remote Update Password
to set the required password when a remote update
to the current active operating profile is made from a command center while the
9602-LP is in the field. The <password> entered must be eight characters in length
and all printable characters are allowed. The factory-set password is 12345678, and
there is no requirement to change this password.
Use
Identifier in Reports
to enter a unique static identifier of up to 50 characters
(platform identifier of the 9602-LP) and add it to the GPS report.
Use
Startup Information
to either display or hide the startup text.
Initial Power State
: The 9602-LP has a single power on/off button. With the correct
internal voltage jumper setting, the 9602-LP is defaulted to turn on automatically