and choose the option “Use”. Then check “Encryption Key” and enter the key two times. Next check the
“Decryption Key” and enter the key two times. When done, click the “Send” button. The message “Update
Made” will be displayed.
After the default Crypto Officer Password has been changed and the Encryption and Decryption Keys have
been set, encryption properties can be modified via the “Change Encryption Settings” window using the current
Crypto Officer Password.
5.3 Miscellaneous Settings
The Miscellaneous tab offers four settings. “Remote Update Password” sets the required password when
a remote update to the current active operating profile is made from a command center while the 9602-LP is
in the field. The <password> entered must be 8 characters in length and all printable characters are allowed.
The factory-set password is 12345678 and there is no requirement to change this password. “Identifier in
Reports” option allows a unique static identifier of up to 50 characters (platform identifier of the 9602-LP) to
be entered and added to the GPS report. The power up text can either be displayed or hidden with the “Startup
Information” option.
The 9602-LP has a single power on/off button. With the correct internal voltage jumper setting, the 9602-
LP is default to power up automatically when DC power is first applied to either pin 1 or pin 9 on the multi-
interface connector. It can be turned off/on again by momentarily holding down the power button and release.
Figure 10.
SatTerm Setup Window for AES-256 Bit Encryption.