9602-LP / 9602-BTI QUICK START GUIDE
451-92750-002B
2023-03-31
Change Voltage Input to +3.6 VDC to +5.3 VDC
IMPORTANT
Power must be disconnected before resetting
the jumper.
1.
Remove the modem’s top plate to find the jumper.
2.
Set the red jumper onto the middle and top pins
as shown in the figure.
NOTE: To reset the input voltage range back to
+6.0 VDC to +32 VDC , set the red jumper onto the
middle and bottom pins.
EMERGENCY MODE
Activate: Quickly press and release the Emergency button
to trigger emergency tracking. When emergency tracking is
active, the Emergency LED illuminates. You can also activate
emergency tracking via input Pin S0.
Deactivate: Press/hold the Emergency button longer than three
(3) seconds to take the 9602-LP out of emergency tracking.
POWER OFF DEVICE
1.
Press the Power button for two (2) seconds to turn off the device.
NOTE: Depending on device configuration settings, press the Power button for two (2) seconds to turn the device
back on.
3
Jumper used to
set input voltage
range
Emergency Button