9602-LP / 9602-BTI QUICK START GUIDE

451-92750-002B

2023-03-31 

Change Voltage Input to +3.6 VDC to +5.3 VDC 

IMPORTANT

Power must be disconnected before resetting

the jumper.
1.

Remove the modem’s top plate to find the jumper.

2.

Set the red jumper onto the middle and top pins 

as shown in the figure.
NOTE: To reset the input voltage range back to 
+6.0 VDC to +32 VDC , set the red jumper onto the
middle and bottom pins. 

EMERGENCY MODE

Activate:  Quickly press and release the Emergency button
to trigger emergency tracking. When emergency tracking is
active, the Emergency LED illuminates. You can also activate 
emergency tracking via input Pin S0.

Deactivate: Press/hold the Emergency button longer than three 
(3) seconds to take the 9602-LP out of emergency tracking

POWER OFF DEVICE
1.

Press the Power button       for two (2) seconds to turn off the device.
NOTE: Depending on device configuration settings, press the Power button      for two (2) seconds to turn the device 

back on.

3

Jumper used to 

set input voltage 

range

Emergency Button