This parameter defaults to 7, equal to all classes, but the A3LA-RM only supports
Voice Call Barring so this is illegal. Therefore in practice the DTE must supply
<classx>=1 when querying or changing the status of any Call Barring facility. When
querying (<mode>=2), <passwd> is irrelevant and should be supplied as ”” in order
to allow the <classx>=1 parameter to be supplied.
For facilities “CS”, “SC”and “FD”, the <passwd> and <classx> parameters are not
relevant and will be ignored if supplied.
Test Command:
+CLCK=?
Test command returns the facility values supported by the phone. The response is in
the form:
+CLCK:(list of supported <fac>s)
Note:
Only “CS” will appear as a supported value if there is no SIM card in the
device.
Note:
+CLCK is closely related to +CPIN and +CPWD. See these commands for
additional information.
B.114
+CPWD
–
C
HANGE
P
ASSWORD
Exec Command:
+CPWD=<fac>,<oldpwd>,<newpwd>
This command sets a new password for the facility lock function defined by the AT
command Facility Lock +CLCK. The following parameter values are currently
supported:
<fac>:
“CS” CNTRL Surface (Phone Unlock Code)
“SC” SIM (SIM Card PIN Code)
“P2” SIM PIN2 (SIM Card PIN2 Code)
“AB” Call Barring password (single password used for all call barring
supplementary services)
Note:
AT+CPWD=”SC”,<oldpwd>,<newpwd> will return “Error” unless the SIM Card
Pin Code is currently activated (see AT command Facility Lock +CLCK).