521-OM0108.88
Copyright
2009 Nalco Company
6-17
Technical Help
(630) 305-CHEM
3D TRASAR
5500 - Installation & Operation Manual
Figure PF9
Note orientation of exit hole.
When reinstalling shield assem-
bly, the shield should be centered
over exit tube and completely
cover it.
6.9.3 Pellet Shield Replacement (con’t)
STEP 6
-
Remove the screws and washers from the tabs of the removed shield.
STEP 7
-
Remove the used pellet shield from the rotor retainer and replace it with a new one.
STEP 8
-
Insert screws and washers into the tabs.
STEP 9
-
If the area around the rotor is full of powder, clean it out to allow the rotor retainer to
fit properly.
STEP 10
-
Insert the entire assembly into the feeder. Be sure to properly align the pellet shield
with the exit tube - the pellet shield should cover the exit tube as shown in the
previous figures. Be sure the washers are in place.
STEP 11
-
Secure the assembly with the screws. Do not over-tighten as the plastic can be
damaged.
STEP 12
-
Turn on power.