3D TRASAR
5500 - Installation & Operation Manual
521-OM0108.88
Copyright
2009 Nalco Company
H-7
Technical Help
(630) 305-CHEM
10.
3D TRASAR Models for High Fouling Applications (Pacific)
The following 3D TRASAR models for High Fouling Applications are available to comply with local
power requirements in the Pacific.
Wall Mount
Models
Frame Mount
Models
Description
060-TRP5515.88
060-TRP5516.88
3D TRASAR for Hi gh Fouling Applications, large backpanel,
Pacific, 240/60, 220/50
060-TRP5525.88
060-TRP5526.88
3D TRASAR for Hi gh Fouling Applications, enclosed large
backpanel, Pacific, 240/60, 220/50
To meet local voltage requirements, 3D TRASAR models for High Fouling Applications (Pacific)
utilize a different pump and solenoid valve. Specifications are shown below.
•
991-05059581.88
Solution pump, Grundfos, DME2, Maximum capacity 0.5 gal/hr, PVDF
pump head, PTFE gaskets and ball valve, 110-240VAC, 50-60Hz.
•
991-05059502.88
Solenoid valve, Stainless Steel body with PTFE seals, 1/4” FNPT,
240VAC/60Hz, 220VAC/50Hz.
Different wire colors are also used in the control box. Specifications are shown below.
Connection
Description
Controller Box
Board Reference
Controller Box
Terminal
Wire Color
Ground
TB9-4
Gnd
Not used
Ground
TB9-3
Gnd
Green with
Yellow Stripe
Neutral
TB9-2
N
Blue
Line Power
TB9-1
L
Brown