3-1. Removing the Monitor Assy (L), (R)
DANGER:
There are areas within the monitor that have high temperature and very
high voltage even after the power has been removed. Extreme care
must be taken to avoid burns or electric shock.
DANGER:
The monitor weighs approx 60kg, at least two people should be used to
remove the monitors.
1)
Ensure that the power is turned OFF before removing the monitors.
2)
Remove the back door from the monitor.
3)
Disconnect the six way video connector and three way power connector. Remove
the hex head screw (M4x10) retaining the earth terminal.
4)
Remove the six security screws (M5x12) on the rear of the main tower assy, and
remove the rear cover (U).
5)
Remove the wiring leading from the main tower to the monitor assy.
6)
Remove the four security screws (M5x12) on the front of the main tower assy,
and remove the acrylic fastener bar and acrylic sheet.
7)
The monitor is fastened on the side and bottom to the main tower assy. Remove
the following bolts:
Side:
Five hex head bolts (M8x45), flat and safety washers.
Bottom: Two hex head bolts (M8x25), flat and safety washers.
WARNING:
If the seat assemblies are not fitted to the tower and only one monitor is
being removed, the tower assembly will be unstable, so remove both
monitor assemblies.