Select OTHER SET on Home Interface to enter into OTHER SET
interface as follow:
Short press button to select the item you would like to modify,
then short press move up and down buttons to modify value of
selected item, then short press button to save and quit, short
pressing button only quits without saving.
The displayed temperature may has big tolerance caused by the
sensor or other factors, so it is necessary to do
temp compensation to room sensor and floor sensor.
Compensation range is -5 ~ +5°C, stepping is 0.5°C.
This parameter can a lso be configured through Advance Config
parameter [11] and [12] .
Other Set
Temperature
Compensation
Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure
after power on again.
If set as “default”, device will go to default mode after power on
again.
This parameter can also be configured through Advance Config
parameter [4].
Re-power
Status
To ensure the safety of the device, if the internal temperature of the
device (not displayed on the interface) is over a certain value during
heating process, the device will execute a short temporary action to
turn off the relay, and the icon will appear on the interface, after
the temperature decreases to a certain value, the device will recover
to work.
Internal Over
Heat Protection