25
© by N&W GLOBAL VENDING SpA
02-2007 266 00
SPECIAL VENDING
It is possible to enable or disable Free Vend, to enable or
disable the “jug facilities” function and to set the number of
consecutive selections (1 to 9; 5 by default) that are
dispensed when “jug facilities” is enabled.
The password and the number of selections for each jug
facilities cycle can be programmed only if the function to
which they are connected is enabled.
A password already used for other functions is not ac-
cepted and a different button combination must be used.
The password must be entered for each special vending
cycle, after pressing button “8” for 2 seconds in normal
vending mode.
SETTING DATE AND TIME
This function is used for setting date and time in the control
software.
AUTOMATIC WASHING OF THE MIXERS
Option of setting the time when automatically cleaning the
mixers and rotating the brewer unit.
When setting the time to 24.00 the function is disabled.
The time must be in the hh.mm. format.
SETTING THE TIME BAND
A time band can be programmed for vending at differenti-
ated prices. This function requires the entry of the start
time and of the end time, which must be in the hh.mm.
format.
SETTING THE TIME BAND PRICES
This function is used for defining the the price of each
single selection when the machine is within the time band
for vending at differentiated prices.
The function is active if the start time and the end time were
set for the time band.
CONSECUTIVE SELECTIONS
It is possible to set the number of consecutive selections
(0 to 99) (dispensed at less than 2 minutes intervals) after
which the machine will not dispense other selections until
the boiler reaches the correct temperature.
With the value set to 0 (default) the function is disabled.
PRE-GRINDING
This function is used for enabling/disabling the grinding of
coffee for the next selection.
This permits the reduction of dispensing time for a coffee
selection. The function is disabled by default.
TEMPERATURE SETTING
With this function, it is possible to set the boiler tempera-
ture directly in "C.
DISPLAYING THE PRE-SELECTION
For semiautomatic models only.
It is possible to set which of the available pre-selection
messages is to be shown on the display.
SYRUP PRE-SELECTION
For semiautomatic models only.
For models with syrup KIT. It is possible to set which of the
available syrup pre-selection messages is to be shown on
the display.
SETTING THE OVERPRICE FOR SYRUPS
For models with syrup KIT. This function is used for setting
an overprice to the selection if drinks with syrups are
selected.
SETTING THE SYRUP CYCLE
For models with syrup KIT. This function is used for setting
if syrups are to be dispensed before or after the selection.
DEX UCS - EVADTS
This function sets the machine in wait mode for the
connection with a device to acquire the EVADTS statistics.
Summary of Contents for Colibri UL 120V
Page 2: ......
Page 4: ......
Page 44: ...N W GLOBAL VENDING S P A Sx39701...
Page 45: ...Colibr UL 120V Schema elettrico funzionale espresso semiautomatico...
Page 46: ...N W GLOBAL VENDING S P A Sx44700...
Page 47: ...Colibr UL 120V Schema elettrico funzionale espresso automatico...
Page 48: ...by N W GLOBAL VENDING SpA NOTE...
Page 49: ...by N W GLOBAL VENDING SpA NOTE...
Page 50: ...by N W GLOBAL VENDING SpA NOTE...
Page 52: ......