© by N&W GLOBAL VENDING S.p.A.
22
05-2015 3625 01
fIllER MENU
sTaTIsTICs
The machine operation data are stored in general and
relative counters that can be reset without losing total
data.
p
riNt
The function is intended to print the data that have been
stored for the machine operation.
Connect an RS232 serial printer having 9600 baud rate,
8 data bits, no parity, 1 stop bit with the serial connector
on the sliding shelf of the user interface.
total
couNtErs
1 - counter by single selection;
2 - counter by band;
3 - failure counter;
4 - coin mechanism data
5 - photocell errors;
6 - motor errors.
7 - dispensing compartment lock errors
rElativE
couNtErs
1 - counter by single selection;
2 - counter by band;
3 - failure counter;
4 - coin mechanism data
5 - photocell errors;
6 - motor errors.
7 - dispensing compartment lock errors
The machine code, the printing date and time, the soft
-
ware release, the operator code and the installation date
of the machine will be also printed.
To print, act as follows:
-
From the print function press the Enter key
to dis-
play “Do you confirm?”;
-
Connect the printer
-
Press the Enter key
to start printing
D
isplay
The function is intended to sequence-display the same
data you can obtain by printing statistics.
Press the Enter key
to sequence-display the follow
-
ing data:
total
couNtErs
1 - counter by single selection;
2 - counter by band;
3 - failure counter;
4 - coin mechanism data
5 - photocell errors;
6 - motor errors.
7 - dispensing compartment lock errors
rElativE
couNtErs
1 - counter by single selection;
2 - counter by band;
3 - failure counter;
4 - coin mechanism data
5 - photocell errors;
6 - motor errors.
7 - dispensing compartment lock errors
r
EsEt
Statistics can be reset for relative counters either glob
-
ally (all types of data) or selectively for:
-selections
-
failures
-coin mechanism errors
-
photocell errors
-motor errors
Press the Enter key
to display the request for confir
-
mation.
Press the Enter key
to reset the statistics. The display
shows the “Running” message during the operation and
statistics are reset.