84
1.
Switch off the filter that needs renewing. The arrow
on the rotary control points towards the filter in op
-
eration.
WARNING !
Be careful that the valve does not pass the closed posi-
tion when the engine is in operation. A closed position
can result in the engine stopping.
2.
Remove the cover from the filter housing.
3. Undo the drain plug.
4. Tighten the drain plug when all the water has emptied.
5. Fill the filter housing with clean fuel.
6. Fit the cover. Tighten the cover screw by hand.
S08
MAINTENANCE
RENEWING THE REVERSIBLE
WATER SEPARATING
PREFILTER
During operation, the arrow on the rotary control should
point towards the filter being used.
ENVIRONMENT
Use a suitable container. The fuel collected must be dis-
posed of as specified in national and international laws
and regulations.
1.
Switch off the filter that needs renewing. During re
-
newal, the arrow on the rotary control points towards
the filter in operation.
WARNING !
Be careful that the valve does not pass the closed posi-
tion when the engine is in operation. A closed position
can result in the engine stopping.
2.
Clean the filter housing externally with a cloth.
3.
Remove the cover from the filter housing.