Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Preset value
0001
h
Firmware version
FIR-v1426
Change history
Description
Value
Description
-32768 … -1
Reserved
0
Immediate stop
1
Braking with "slow down ramp" (deceleration (deceleration ramp) depending
on operating mode) and subsequent state change to "Switch on disabled"
2 … 32767
Reserved
605Ch Disable Option Code
Function
This object contains the action that is to be executed on a transition of the CiA 402 Power State
Machine from the Operation enabled state to the Switched on state.
Object description
Index
605C
h
Object name
Disable Option Code
Object Code
VARIABLE
Data type
INTEGER16
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
0001
h
Firmware version
FIR-v1426
Change history
Description
Value
Description
-32768 … -1
Reserved
0
Immediate stop
1
Braking with "slow down ramp" (deceleration (deceleration ramp) depending
on operating mode) and subsequent state change to "Switch on disabled"
2 … 32767
Reserved
Version: 1.0.1 / FIR-v1748
235