Technical Manual PD4-E-M (EtherCAT)
7 Special functions
Signal
sources
Selection of
source with
3252:NN high byte
Bits of 60FE
h
:01
Selection of
control bit with
3252:NN low byte
Ouput
Activation
This mode is activated by setting object 3250
:08
h
(Routing Enable) to 1.
Note
Entries 3250
h
:01
h
h
then have no function until "Output Routing" is switched off again.
Routing
The subindex of object 3252
determines which signal source is routed to which output. The output
assignments are listed in the following:
Subindex 3252
h
Output Pin
01
h
Configuration of PWM output (if available)
02
h
Configuration of output 1
03
h
Configuration of output 2 (if available)
04
h
Configuration of output 3 (if available)
05
h
Configuration of output 4 (if available)
Note
The maximum output frequency of output 1 and output 2 is 10 kHz; of the PWM output it is 2 kHz.
All other outputs can only produce signals up to 500 Hz.
h
:01
h
to 05
h
are 16 bits wide, whereby the high byte selects the signal source (e.g., the
PWM generator) and the low byte determines the control bit in object 60FE
:01.
:01
h
to 05 inverts the controller from object 60FE
h
:01. Normally, value "1" in object
h
:01 switches on the signal; if bit 7 is set, the value "0" switches on the signal.
Number in 3252:01 to 05
00XX
h
Output is always "1"
Version: 1.0.1 / FIR-v1748