Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Data type
UNSIGNED32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 00000032
h
•
PD4-E601L42-M-65-1: 00000032
h
•
PD4-EB59CD-M-65-1: 00000003
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: "Savable" entry changed from "no" to
"yes, category: tuning".
2031h Maximum Current
Function
t monitoring is not active, the rms current specified in the motor data sheet is entered here in mA.
If Closed Loop mode is used or if I
t monitoring is activated, the maximum current value is specified
here in mA.
Within the controller, the entered value is always interpreted as the root mean square.
Object description
Index
2031
h
Object name
Maximum Current
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
•
PD4-E591L42-M-65-1: 00000834
h
•
PD4-E601L42-M-65-1: 00000834
h
•
PD4-EB59CD-M-65-1: 00001770
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1614: "Savable" entry changed from "yes,
category: application" to "yes, category: tuning".
Firmware version FIR-v1614: "Object Name" entry changed from
"Peak Current" to "Max Current".
2034h Upper Voltage Warning Level
Function
This object contains the threshold value for the "overvoltage" error in millivolts.
Version: 1.0.1 / FIR-v1748
151