Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
205Bh Clock Direction Or Clockwise/Counter Clockwise Mode
Function
This object can be used to switch the clock-direction mode (value = "0") to the right/left rotation mode
(value = "1").
Object description
Index
205B
h
Object name
Clock Direction Or Clockwise/Counter Clockwise Mode
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1504
Change history
2084h Bootup Delay
Function
Defines the period between the time that supply voltage is applied to the controller and the functional
readiness of the controller in milliseconds.
Object description
Index
2084
h
Object name
Bootup Delay
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
2101h Fieldbus Module Availability
Function
Shows the available fieldbuses.
Version: 1.0.1 / FIR-v1748
166