Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
E-IP
Value = "1": The used protocol is EtherNet/IP
™
.
2102h Fieldbus Module Control
Function
This object can be used to activate/deactivate certain fieldbuses (physical interfaces and protocols).
Object description
Index
2102
h
Object name
Fieldbus Module Control
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: communication
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000020
h
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1626: "Savable" entry changed from "yes,
category: application" to "yes, category: communication".
Description
h
:1
h
contains all physical interfaces/protocols that can be activated/deactivated. These can
be switched in this object (2102
h
). The current status of the activated fieldbuses is in object 2103
h
:2
h
.
The following distribution of the bits applies here:
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MTCP MRTU
E-IP
15
14
13
12
11
10
9
8
E-CAT
7
6
5
4
3
2
1
0
E-NET
SPI
RS485 USB
CAN RS232
USB
USB interface
RS-485
RS-485 interface
RS-232
RS-232 interface
CAN
CANopen interface
E-NET
EtherNet interface
Version: 1.0.1 / FIR-v1748