Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
4014h Operating Conditions
Function
This object is used to read out the current environment values for the controller.
Object description
Index
4014
h
Object name
Operating Conditions
Object Code
ARRAY
Data type
INTEGER32
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 01 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 02 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Name" entry changed from
"Temperature PCB [d?C]" to "Temperature PCB [Celsius * 10]".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 03 changed from "read/write" to "read only".
Firmware version FIR-v1738-B501312: The number of entries was
changed from 4 to 6.
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
05
h
Subindex
01
h
Name
Voltage UB Power [mV]
Data type
INTEGER32
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Version: 1.0.1 / FIR-v1748