Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Description
The subindices have the following functions:
•
01
h
:
•
Value ="0"
h
: The special drive modes are switched off
•
Value="2"
h
: The special drive modes are switched on and the mode is set in subindex 02
h
.
•
02
h
: Defines the used mode.
4016h Factory Settings
Function
This object indicates whether Auto setup was executed in production.
Object description
Index
4016
h
Object name
Factory Settings
Object Code
ARRAY
Data type
UNSIGNED8
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1738-B501312
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
01
h
Subindex
01
h
Name
Factory Autosetup Done
Data type
UNSIGNED8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Version: 1.0.1 / FIR-v1748