Cautions when using disinfectant 

1.

2.
3.
4.
5.

6.

7.

8.

9.

Never mix disinfecting water with other disinfectant, abstergent and chemicals.
(But, it can be used with kitchen detergent in some case.)
If you have sensitive skin, wear protective equipment such as rubber gloves.
Do not use disinfectant in the cultivation of plants, animals, fish and shellfish, etc.
Be careful that the solution may bleach the colored textiles.
Be aware of the 

Corrosion-resistant table

 on the right side, so please wash it once with 

tap water after using.
Be sure to wash the 

Metal-drainage-pipe

 with tap water after using the large amount of 

disinfectant, because it may cause corrosion.
Chlorine  concentration  may  be  degraded  by  ultraviolet  rays,  high  temperature  or  long 
period of time.
If the saline solution remains in the tank for an extended period of time, it may cause cor-
rosion.
If you exceed the available chlorine concentration, rinse with tap water after using the 
disinfectant.

※Please  do  not  spray  on  the  materials  which  are  listed  on  the  right  table  marked  as  
‘weak’.

Cautions

An analysis table for corrosion-resistant material      

Materials

ABS resin
polyethylene
acrylic
polypropylene
teflon
silicon
epoxy resin
urea resin
Butyl-rubbe, NBR
natural, urethane rubber
titanium, glass, ceramics
stainless steel
plating, copper

phosphor bronze
brass
aluminium alloy
steel

Corrosion resistance

4. Inspection  > 

 

Cautions

 / Troubleshooting / Replacement period & Block diagram 

Summary of Contents for DES-WA50

Page 1: ...ower Prevent Disease such as Food poisoning Safe to Human Body Harmless and Environment Friendly Product Almost No Residual Chlorine Please read the manual before installing or using the device High pressure sterilizing washer NaOClean Manual www naoclean com ...

Page 2: ...1 Cautions for using 2 About product Components Specification Features How to use Applications 3 Using refined salt Cautions Making saline solution 4 Inspection Cautions Troubleshooting Replacement period Block diagram Certifications ...

Page 3: ...eep the device away from the children or unskilled people You can prevent from unexpected situations by keeping your pace constantly while using the device Do not disconnect the gun from the hose as long as the pressure remains Because the high pressure water inside the hose may spurt and hurt the user Do not leave the motor idling for a long time A long time idling may cause the damage of the mot...

Page 4: ...places Never spray water or any solution on the main unit or a person Keep the Spray gun hose away from the hot air exhaust Unplug before moving the device Be careful when you fill the water or clean inside the tank because there is a water level controller Only use the tap water or suitable for drinking water standards Do not use hot water When you are not using disinfecting water please turn off...

Page 5: ...oclean com 2 About product Components Specification Features How to use Applications Front Hose reel handle Hose reel Cover Storage tank Main body Front panel Handle Drain valve Spray gun Urethane wheel Hanger Back ...

Page 6: ...se Applications Accessories box Level indicator Nozzle 25 40 degrees Earth leakage circuit breaker Right Left Nut cover Pump connection hose Accessories Pressure controller Measuring cup Dilution bottle Oil tray Botle for changing the pump oil Detergent bottle Option ...

Page 7: ...ess Disinfectant button the lamp is turned on Disinfectant button It generates disinfectant Power switch The power is switched on and motor is working You can use the water from the high pressure spray gun Power lamp When you press the Power switch the lamp is turned on Error lamp If you put too much salt Error lamp is turned on Disinfectant generating lamp When the lamp was turned on it means dis...

Page 8: ...agent Do not remain strong smell No residual toxicity Safe for humans and environment 4 Portability and effectiveness Easy to move with the storage tank s wheel Conveniently usable in a small or narrow spaces with high pressure spray gun Practically no restriction of operation as far as electric power is available Features Specification Model Dimension Rated Voltage Weight Storage tank Max pressur...

Page 9: ... page 12 Detergent bottle Option Using a detergent bottle Option There is an angle of 25 degrees green nozzle and 40 degrees white nozzle Choose the type of spray nozzle Push the connector to the back and change the nozzle After that turn it back as original place Do not put your face on the front of the gun when the device is working How to change the nozzle When it s difficult to roll or unroll ...

Page 10: ...ed for a long time When the surrounding temperature drops to below zero degrees please stop using the device and completely drain water inside the tank After using the device At first pressure is set as 100bar How to adjust the pressure Loosen one screw and take the pliers out Use the pliers on the lower part Adjust the pressure by turning the pliers from side to side into the hole You have to dra...

Page 11: ...using the disinfectant please refill the tank with tap water and clean inside the device by running it once again Make sure to dissolve the prescribed amount of salt completely before pouring it into the tank Too much salt may cause an er ror preventing disinfectant from being generated In such a case turn off the Disinfectant button drain some of the salt water from the tank by pulling the spray ...

Page 12: ... and shoot it You can choose the type of spray nozzle How to wash with water 1 2 3 4 5 6 Add tap water as much as needed in the tank Remove the nozzle from the front of the gun and replace it with the detergent bottle Detergent bottle is option Connect the power plug and press the main Power switch Spray detergent on areas stained with greasy dirt After some moment remove the detergent bottle and ...

Page 13: ... and prevents secondary pollution generated from them Floor drain stairs and all around the workplaces It disinfects effectively and removes bad odor in many places where should be cleaned including fish meat processing fac tories feeding facilities kitchens floor drain and all around the workplaces Machines Equipments 2 About product Components Specification Features How to use Applications Work ...

Page 14: ...uring it into the tank The salinity of salt should be 88 or higher Never use roasted salt or salt used for cooking that contains citric acid or amino acid Cautions before using salt 1 2 3 4 Turn off the Disinfectant button Drain some of the saline solution from the tank by pulling the gun trigger Add some water into the tank to lower the concentration of the salt Turn on the Disinfectant button an...

Page 15: ...lt in the Dilution bottle Add the water up to 2 3 and shake the bottle sufficiently The salt have to be completely melted Pour the solution into the tank Add the water up to 50 or 25L line of the tank Correct measurement of salt using Measuring cup 50L Dissolve salt with water Add water up to 50L Granule type salt salinity 88 200g 250g 150g Powder type salt salinity 99 Dissolve salt with water Add...

Page 16: ...isinfectant because it may cause corrosion Chlorine concentration may be degraded by ultraviolet rays high temperature or long period of time If the saline solution remains in the tank for an extended period of time it may cause cor rosion If you exceed the available chlorine concentration rinse with tap water after using the disinfectant Please do not spray on the materials which are listed on th...

Page 17: ...oluntarily modify or repair the parts inside the device Measure supply voltage and see if it is a proper range Check the power cord for cracking or try another socket Turn off the power and wait until the overheated motor cools down Turn on the ELCB again Pull out a Rubber stopper and raise the ELCB switch on the left side of the body Disconnect the nozzle from the gun and dust debris inside the e...

Page 18: ...drain the oil 3 Fill certain amount of kerosene into and clean up 4 After draining the kerosene please fasten the cover with screwdriver and fill the oil into and then close the cover 5 Remove the Oil tray and fasten the last cover with screwdriver The level of the oil must be checked periodically The most important is that the oil must be changed after the first 50 hours of work and successively ...

Page 19: ...Patents Patent pending Water cleaning disinfectant genertating and spraying device Patent 10 0730612 Portable disinfectant generator Utility model 20 0425129 Country of destination Australia Indonesia Malaysia Singapore Thailand United King dom of Great Britain CE ISO 9001 Certificated INNO BIZ ...

Page 20: ...roduct Damage during transportation due to mishandling Connection to a wrong power Please fill out the quality warranty completely and keep it carefully Consumer damages compensation If you find any abnormality or have a question while using this product please contact a nearby distributor or our head office In order to request for services you need to present this quality warranty duly filled out...