background image

Rev. 08/30/05

Nipple

Tools of this class operate on a 
wide range of air pressures. It is 
recommended that air pressure of 
these tools measures 90 PSI at the 
tool while running free. Higher 
pressure 

(over 90 psig; 6.2 bar)

 raises 

performance beyond the rated 
capacity of the tool, which will 
shorten tool life because of faster 
wear and could cause injury.

Always use clean, dry air. Dust,  
corrosive fumes and/or water in  
the air line will cause damage to 
the tool. Drain the air tank daily. 
Clean the air inlet filter screen on 
at least a weekly schedule. The  
recommended hookup procedure 
can be viewed in the above figure.

The air inlet used for connecting 
air supply, has standard 1/4" NPT. 

Line pressure should be increased 
to compensate for unusually long 
air hoses (over 25 feet). Minimum 
hose diameter should be 3/8" I.D. 
and fittings should have the same 
inside dimensions and be tightly 
secured.

Lubricate the air motor daily with 
quality NAPA air tool oil. If no air 
line oiler is used, run a teaspoon of 
oil through the tool. The oil can be 

squirted into the tool air inlet or 
into the hose at the nearest  
connection to the air supply, then 
run the tool. The amount of oil to 

be used is one ounce. Overfilling 
will cause a reduction in the power 
of the tool.

 AIR SUPPLY

 LUBRICATION

PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MANUAL FOR FUTURE REFERENCE.

3

WARRANTY  POLICY: 

NAPA  PROFESSIONAL  AIR  TOOLS  are  warranted  against  defects  in  material  and  

workmanship for a period of one (1) year from the date of the original purchase. We will repair or replace 
at our option any defective part or unit which proves to be defective in material or workmanship during 
this  one  year  period.  ALL  NAPA  PROFESSIONAL  AIR  TOOLS  must  be  repaired  only  by  authorized  NAPA 
PROFESSIONAL  AIR  TOOL  Service  Centers.  This  warranty  does  not  cover  damage  to  tools  rising  from  
alteration, abuse, misuse and does not cover any repairs made by anyone other than an authorized NAPA 
PROFESSIONAL AIR TOOL Warranty Center. Tools sent to a Warranty Center in a dissembled condition will 
not be covered as a warranty repair.
Return  tools  to  Service  Centers  transportation  prepaid.  Be  certain  to  include  your  name,  address  and 
phone number along with proof of purchase information, with each tool.

6-787_Manual_100705.indd   3

10/7/05   8:16:25 AM

Summary of Contents for 6-787

Page 1: ...hemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with a...

Page 2: ...ation of the work piece or tool causeing injury to arms and or shoulders Enough torque is generated to cause falls Always use sharp bits Use less downward pressure at breakthrough Do not lubricate too...

Page 3: ...ir inlet or into the hose at the nearest connection to the air supply then run the tool The amount of oil to be used is one ounce Overfilling will cause a reduction in the power of the tool AIR SUPPLY...

Page 4: ...while the motor is is running then turn off the drill If the drill jams in the work release throttle immediately Disconnect the drill before removing bit and determining cause of trouble Do not attem...

Page 5: ...24 1 26 RS78726 Lock Ring 1 27 RS227B25 Ball Bearing 1 Ref Item DESCRIPTION QTY 28 RS78728 Spacer 1 29 RS78729 Oil Cap 1 30 RS78730 Pinion 1 31 RS78731 Angle Housing 1 32 RS78755 Spindle 7mm 1 34 RS7...

Page 6: ...m bent or jammed with dirt particles YOU SHOULD Remove assembly and install new O ring Lubricate with air tool oil and operate trigger briskly If operation cannot be restored tool should be serviced a...

Page 7: ...os productos de mamposter a y Ars nico y cromo de maderas tratadas qu micamente El riesgo ante estas exposiciones var a dependiendo de cuan frecuente usted haga este tipo de trabajo Para reducir la ex...

Page 8: ...durante periodos prolongados pueden ser da inos a sus manos y brazos Interrumpa el uso de la herramienta si sobreviene una incomodidad una sensaci n de cosquilleo o un dolor Solicite una opini n m di...

Page 9: ...PT Debe aumentar la presi n de la manguera para compensar las mangueras del aire que sean extraordinariamente largas m s all de 7 6 m El di metro m nimo de la manguera debe ser de 9 5 mm 3 8 D I y los...

Page 10: ...el trabajo mientras que el motor gira despu s apague el taladro Si la broca se atasca dentro del trabajo afloje inmediatamente el gatillo Desconecte el taladro antes de quitar la broca y determine la...

Page 11: ...ice con casquillos de cromo LA HERRAMIENTA PIERDE LENTAMENTE SU POTENCIA PERO FUNCIONA SIEMPRE A TODA VELOCIDAD LIBREMENTE La causa probable Partes gastadas del embrague causadas por una lubrificaci n...

Page 12: ...el aire Haga funcionar el gatillo en golpes cortos Desconecte el abastecimiento del aire gire manualmente el mandril vac o y cerrado del taladro Vuelva a conectar el abastecimiento del aire Si los res...

Reviews: