background image

8

WI1024B 2WAY-UNIVKF

 

Installation Instructions

STEP 1

  -   WIRING AND CONFIGURATION

Mounting

The 2 way receiver should be mounted in a location which is centrally located
in the area of anticipated usage. It is not recommended that the receiver be
installed in an attic or mounted within 24 inches of any metallic objects.
Installation in a basement will result in reduced range. It should not be mounted
in the control panel enclosure. The receiver should be positioned  with the
antennas pointed up.

Wiring

The 2WAY-UNIVKF is compatible with the keypad bus of the NAPCO Gemini
GEM-P816, GEM-P1632, GEM-P3200 and GEM-P9600 control panels. It is
also compatible with the keypad bus of the Ademco models Vista 10 and 20.
Note: for Bus Operation, DO NOT connect any wires to terminals 5 & 6.

Programming

The Gemini control panel must be programmed for an additional keypad. 

For

example if the installation currently has 2 keypads, an additional keypad,
keypad # 3 must be enabled in programming.

 This is not required for the

Ademco Vista 10 and 20.

If KeyFob panic is desired, Keypad Panic should be enabled in the control
panel program. For the Ademco Vista 10 and 20, zone 95 must be programmed
for 24 Hr Audible or 24 Hr Silent. For the Vista 20 zone 99 must be
programmed  for 24 Hr Audible or 24 Hr Silent.

Configuring the Receiver Address

For the NAPCO Gemini bus operation, the receiver must be addressed to
match the address of the additional keypad enabled in programming above. 

For

example, if the receiver is to be addressed as keypad 3, refer to the Receiver
Address Chart and install the appropriate address jumpers (J8 off, J9 ON,
J10 ON). This is not required for the Ademco Vista 10 and 20.

Configuring the Control Panel Type

For a bus compatible installations only, refer to the Panel Type Configuration

RECEIVER

GND

+12V

TX

4

1

2

3

RX

12

9

10

11

RED

BLACK

GREEN

YELLOW

 

 GEMINI PANEL

 RECEIVER ADDRESS CHART

KEYPAD

ADDRESS JUMPERS

#

J8

J9

J10

1

off

off

off

1

off

off

ON

2

off

ON

off

3

off

ON

ON

4

ON

off

off

5

ON

off

ON

6

ON

ON

off

7

ON

ON

ON

PANEL TYPE CONFIG. CHART

PANEL TYPE

CONFIG.  JUMPERS

J3

J4

J5

NAPCO GEM-P816, P1632, P3200, P9600

off

off

off

Ademco Vista 10, 20

off

off

ON

Ademco 40, 50

off

ON

off

RECEIVER

GND

+12V

TX

4

1

2

3

RX

RED

BLACK

GREEN

YELLOW

 

ADEMCO PANEL

NAPCO Gemini & Ademco Bus Operation

Summary of Contents for 2WAY-UNIVKF

Page 1: ...WI1024B 03 01 NAPCO 2001 2WAY UNIVKF Bi Directional LCD KeyFob Installation Instructions...

Page 2: ...per miniaturized for portability yet packs tremendous sales potential and consumer market appeal System Status is indicated through 8 intuitive ICONS a lock a house a flame etc on the LCD display acco...

Page 3: ...all relays active Operating Temperature 0 49 C 32 120 F Maximum of KeyFobs supported 7 Dimensions Receiver 6 3 4 X 3 5 8 X 1 1 2 KeyFob 2 X 1 3 8 X 1 2 Relay Contact Rating 1A 24 VDC KeyFob Battery 1...

Page 4: ...m refer to the section which applies to the type of installation at hand Bus or Universal Operation and follow all indicated steps Bus Mode Features Keyfob Commands Arm Disarm Stay Mode Arming Panic G...

Page 5: ...elay 3 N O Relay 3 COM Relay 3 N C RES RE4 RE3 RE2 RE1 R2T AR A3 A2 A1 Reserved J1 Invert Stay Mode PGM J2 Panel Type J3 Panel Type J4 Panel Type J5 Relay 2 momentary J6 Reserved J7 Keypad Address J8...

Page 6: ...will appear accom panied by the appr opriate beep s see Audible Indicators The icon s will automatically go out in about 6 seconds ON OFF AND Press ON OFF and simultaneously to activate lighting or o...

Page 7: ...med The system is armed System Ready The system is disarmed with all zones secure The system is ready to arm Transmit Each time a button is pressed the transmit ICON will light to indicate that the Ke...

Page 8: ...ic is desired Keypad Panic should be enabled in the control panel program For the Ademco Vista 10 and 20 zone 95 must be programmed for 24 Hr Audible or 24 Hr Silent For the Vista 20 zone 99 must be p...

Page 9: ...Fob will sound a confirmation beep Repeat for each KeyFob to be enrolled Press RESET on Keypad OR ON OFF on Keyfob Exit Enroll Mode the Enroll Mode LED will go out All instructions which require keyst...

Page 10: ...eeding a 4 digit User Code representing each KeyFob must be programmed into the control panel 1 Arm system from any keypad 2 Disarm system from any keypad 3 Enter Unique Code 1113 ON OFF STAY Enroll M...

Page 11: ...tivate Relay 1 or Relay 2 Relay Control groups 1 2 are also simultaneously activated allowing control of external relays and or X 10 devices connected to the control panel Press to momentarily activat...

Page 12: ...C D E F G NEXT YES PRIOR NO AREA SYSTEM ARMED 01 01 00 12 00 AM 2WAY Garage Door Control Door 1 Door 2 Appliance Typical Gemini control panel application controlling 2 Garage doors and X 10 devices a...

Page 13: ...on the the control panel Panic Zone Zone programmed for 24 hour panic Typical Panic wiring for a zone using End of Line resistors Zone programmed for 24 hour panic Typical Panic wiring for a zone doub...

Page 14: ...the button on KeyFob 1 The KeyFob will sound a confirmation beep 3 Press the button on KeyFob 2 if more than one The KeyFob will sound a confirmation beep Repeat for each KeyFob to be programmed into...

Page 15: ...pass the correct status to the KeyFob Typical connection will be to the bell output of the control panel It will automatically display a siren icon for a steady input and a fire icon for a pulsing or...

Page 16: ...roviding perimeter protection only Choose the appropriate wiring scheme for your control panel When KeyFob button ON OFF is pressed the PGM terminal of the receiver will cause a violation of the exit...

Page 17: ...diagram below Pressing the button will provide a 2 second short across these terminals prompting the garage door opener to activate Garage door opener wall mounted push button switch or normally open...

Page 18: ...196 X 197 X 4 For BOTH Fire AND Burg sense 2 IN4001 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2WAY UNIV Garage Door Control VVV 3 9K KEYSWITCH ARM NOTES 1 Enable Keyswitch Input on Z...

Page 19: ...2 0 3 Program Panic Zone Example Zone 7 24 Hour Silent Location 25 Segment 7 7 and other appropriate options such as reporting audibles etc 4 Enable Automatic Interior Bypass Location 23 Segment 1 3...

Page 20: ...APCO be liable for an amount in excess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure...

Reviews: