L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 19
WI1502A 9/06
GLOBAL SYSTEM EVENT/TROUBLE
SYSTEM RESPONSE
ACTIVATED BY GLOBAL
EVENT/TROUBLE
ADDR
TEST
TIMER
TELCO
FAILURE
RF RCVR.
TROUBLE
MEMORY
FAILURE
LOW
BATTERY
AC FAIL
EZM
TAMPER
Bell
Superv
1
2
3
4
5
6
7
8
Alarm Output
0836
Pulsed Alarm Output
0837
PGM1 Output
0838
PGM2 Output
0839
Report Event Telco 1
0840
Report Restore Telco 1
0841
Report Event Telco 3
0842
Report Restore Telco 3
0843
SYSTEM OPTIONS (ADDRESS 0836-0871 & 2045)
1. Select the desired option entering the option number (1-8) for each digit.
2. Enter corresponding option number in address location.
NOTE:
Dark shaded data value box shows option not available. Press
U
to save.
GLOBAL AMBUSH CODE:
For GEM-K Series keypads, it is the 2-digits entered immediately prior to
the regular disarm code. If “Enable Global Ambush Code” (Address 1422) is selected and Address
2045 is left blank (•), then the 2-digit Global Ambush Code is “99”. If “Enable Global Ambush Code” is
selected and Address 2045 is
not
left blank (•), then the 2-digit Global Ambush Code is the two digits
entered in address 2045. For Touchpads, see "Ambush" glossary entry in install instructions WI1501.
Enter in address location (both 1st and 2nd digits); valid entries are 1-9. Press
ENTER
to
save.
Note:
Do not program in CP-01 compliant systems.
[Default = blank (•) blank (•)]
Global
1st digit 2nd digit
Ambush Code
ADDRESS 2045
SYSTEM RESPONSE
ACTIVATED BY AREA 1
EVENT/TROUBLE
AREA 1 SYSTEM EVENT/TROUBLE
ADDR
AMBUSH
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUX.*
KEYPAD
TAMPER
FAIL TO
OPEN
FAIL TO
CLOSE
Keyfob
Low Batt
1
2
3
4
5
6
7
8
Pulsed Alarm Output
0856
Alarm Output
0857
PGM1 Output
0858
PGM2 Output
0860
Report Event Telco 1
0861
Report Event Telco 3
0863
[Default = blank (•) from address 0856-0863]
* NOTE:
Keypad Aux. is not to be selected for UL Installations.
SYSTEM RESPONSE
ACTIVATED BY AREA 2
EVENT/TROUBLE
AREA 2 SYSTEM EVENT/TROUBLE
ADDR
AMBUSH
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUX.*
KEYPAD
TAMPER
FAIL TO
OPEN
FAIL TO
CLOSE
Keyfob
Low Batt
1
2
3
4
5
6
7
8
Pulsed Alarm Output
0864
Alarm Output
0865
PGM1 Output
0866
PGM2 Output
0868
Report Event Telco 1
0869
Report Event Telco 3
0871
[Default = blank (•) blank (•) from address 0864-0871]
* NOTE:
Keypad Aux. is not to be selected for UL Installations.
[Default = blank (•) from address 0836-0843].
Note:
If
Test Timer
is enabled (above),
Digital Dialer Test
is also enabled.
DI
RECT A
D
DRESS PROGRA
M
MODE