L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 27
WI1502A 9/06
Default depends on Easy Menu Driven Program Mode question "
# OF ZNS IN
AREA 1 ENTER # ZONES
" and "
EZ ZONE DOUBLING? Y/N
". For example, if 64
Zones are used and Zone Doubling is
not
enabled, then all 14 Groups will be
automatically enabled. If 64 Zones are used and Zone Doubling is enabled,
then only Groups 1-12 will be automatically enabled.
NOTE:
If "Zone Doubling" (Address 1423, option 1) is
not
enabled, then Zones 1-8 are included in the control panel
and Zones 9-64 (Groups 1-14) are EZM Zones. If "Zone Doubling" is enabled, then Zones 1-16 are included in the
control panel and Zones 17-64 (Groups 1-12) are EZM Zones (and Groups 13 and 14 must not be used).
EZM GROUP OPTIONS:
Up to 14 Groups of 4 Zones each may be pro-
grammed depending on the number of Zones used and which EZM mod-
ules are connected. Each Group represents 4 Zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations
above.
NOTE:
Dark shaded data value box shows option not available.
3. Press
U
to save.
EZM GROUP OPTIONS (ADDRESS 1455-1468)
EZM Group 1
ADDRESS 1455
EZM Group 2
ADDRESS 1456
EZM Group 3
ADDRESS 1457
EZM Group 4
ADDRESS 1458
EZM Group 5
ADDRESS 1459
EZM Group 6
ADDRESS 1460
EZM TYPE
DATA
ENTRIES
OPTION
blank (•)
Not used
(No EZM
present)
1
4-Zone EZM
EZM Group 7
ADDRESS 1461
EZM Group 8
ADDRESS 1462
EZM Group 9
ADDRESS 1463
EZM Group 10
ADDRESS 1464
EZM Group 11
ADDRESS 1465
EZM Group 12
ADDRESS 1466
EZM Group 13
ADDRESS 1467
EZM Group 14
ADDRESS 1468
EZM
GROUP
NORMAL
DOUBLED
1
9-12
17-20
2
13-16
21-24
3
17-20
25-28
4
21-24
29-32
5
25-28
33-36
6
29-32
37-40
7
33-36
41-44
8
37-40
45-48
9
41-44
49-52
10
45-48
53-56
11
49-52
57-60
12
53-56
61-64
13
57-60
14
61-64
ZONES COVERED
AREA ARMING OPTIONS (ADDRESS 1469-1472)
PRIORITY AREA ARMING:
1. Select option from the table shown.
2. Enter either blank (•) or "1" in corresponding address location.
NOTE:
Dark shaded data value box shows option not available.
3. Press
U
to save.
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
blank (•)
Not Used
Enabled
1
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
blank (•)
Not Used
Enabled
1
Priority
Arming
Area 1
ADDRESS
1469
[Default = blank (•)]
Priority
Arming
Area 2
ADDRESS
1470
[Default = blank (•)]
PRIORITY ARMING/AREA 3
DATA ENTRIES
OPTION
blank (•)
Not Used
Enabled
1
PRIORITY ARMING/AREA 4
DATA ENTRIES
OPTION
blank (•)
Not Used
Enabled
1
Priority
Arming
Area 3
ADDRESS
1471
[Default = blank (•)]
Priority
Arming
Area 4
ADDRESS
1472
[Default = blank (•)]
DI
RECT A
D
DRESS PROGRA
M
MODE