NAPCO Security Systems
GEM-P1632 Installation Instructions
WI808B 8/98
Page 11
The GEM-P1632M can be used as part of a UL Central
Station Grade C, B, or A installation. Normally, a digital
communicator is classified as Grade C and may be classi-
fied Grade B if used with the specified Grade-A Local bell
and bell housing. A UL Central Station Grade-A installation
requires the use of a Napco RM3008 Relay Board and
Ademco 7720 Radio System. Refer to the installation
instructions furnished with each component for respective
installation requirements.
For a UL Commercial Grade-A Police Station Connection,
refer to GRADE-A LOCAL MERCANTILE INSTALLA-
TIONS, which follows. Use the M278 Line-Reversal Moni-
tor to provide basic line security; refer to the instructions
accompanying the M278 for other installation require-
ments.
For UL Commercial safe and vault applications, use a
UL-listed shock sensor suitable for metal enclosures. In-
stall tamper switches on front and rear of control-panel
enclosure.
Grade-A Local Mercantile Installations
A Grade-A Local Mercantile installation must use at least a
6.0AH standby battery. Programming must include Auto
Bell Test on Arming. Trouble on Night Open may not be
programmed for any zone.
The minimum requirements for a listed Grade-A Local
system include:
Low-Battery Annunciation.
An Ademco AB-12 Bell and Box (12-volt).
Program Auto Bell Test on Arming.
a maximum Entrance and Exit Delay of 60 seconds.
Interfacing to the Ademco 7720 Long-Range Wireless System
The RM3008 may be used to interface the GEM-P1632M control panel to the Ademco 7720 transmitter in order to meet
UL Central Station Grade-A or Grade-B requirements by using a digital communicator combined with one-way wireless.
(Normally, a digital communicator is Grade C, and may be Grade B if the specified Grade-A local bell is used.) Refer to
the wiring diagram which follows, and to the instructions furnished with the Napco and Ademco equipment for further
information concerning the DACT, listed compatible receiver and formats, Grade-A local bell and bell housing. Enable
Line Fault Test must be programmed.
Central Station Grade-B Requirements (Pending)
Wiring to the Ademco 7720 transmitter must be enclosed in rigid conduit when outside walls, or in flexible conduit when
inside walls or above ceilings, for the entire length up to the transmitter room. The transmitter room must be protected by
a UL listed intrusion detection unit that is connected to one of the input channels of the Ademco 7720. Relays must be
programmed to trip the Ademco 7720 for alarms on all protective circuits, including tampers, telco phone failure, 24-hour
test timer, transmitter low battery and ac loss. (See PCD3000 External Relay Control screen.) One zone on the
GEM-P1632M, programmed as a 24-Hour Zone, must supervise the radio.
Central Station Grade-A Requirements (Pending)
In addition to Grade-B Requirements (above), one relay on the RM3008 must be programmed to trip the Ademco 7720
when the telephone line fails. Daily openings and closings are required to be transmitted by the Napco panel along with
the 24-hour DACT test signal and DACT trouble conditions.
IN
STA
LLA
TI
ON