background image

Overview of the NAPCO iBridge

®

 IBR-ZREMOTE Z-Wave

®

 Controller 

General Overview 

The iBrid

ge

®

 IB

R-ZREMOTE is a Local and Remote Control Module and Z-

Wave

®

 Controller that allows control of security, video, locking, lighting and 

climate control from inside or outside your home.  Z-Wave devices may be 
enrolled, removed and formed into a Z-Wave wireless home control 
network, and also integrated with Napco's iBridge suite of services that 
includes access to the iSee Video remote video Internet monitoring 
system. 
Compatibility with the iSee Video VideoAlert system allows an email or text 
message to be sent when a selected control panel event occurs.  In 
addition, acting as a wireless Z-Wave controller, the IBR-ZREMOTE can 
trigger Z-Wave network devices upon control panel events.  For example, 
upon system arming the IBR-ZREMOTE can turn lights on or off, adjust 
thermostats, email video clips, etc. 
The IBR-ZREMOTE is wired to the control panel keypad bus, and 
continually monitors all changes to the status of the system and triggers 
actions based on user or dealer entered programming.   

Note:

  This device is a security enabled Z-Wave product that is able to 

use encrypted Z-Wave messages to communicate to other security 
enabled Z-Wave products.  This product can be included and operated in 
any Z-Wave network with other Z-Wave certified devices from any other 
manufacturers.  All constantly powered nodes in the same network will act 
as repeaters regardless of the vendor in order to increase reliability of the 
network.  For an 

iBridge Z-Wave Evaluated Device List

, see our website 

at 

www.napcosecurity.com/ibridge.html

 

iBridge Online 

To access the IBR-ZREMOTE remotely via PC, tablet or smart phone, or 
to provide remote services for a customer, the dealer must have an iBridge 
online account.  Go to 

www.ibridgeonline.com

 to access your existing 

account or register for a new account.  Device apps are available for 
iPhones, iPads and Android devices from their respective apps markets.   
 

Remote Control 

With the IBR-ZREMOTE

, actions performed at the keypad can be 

performed remotely

.  Add the IBR-ZREMOTE to a Napco control panel by 

simply programming an additional keypad address into the control panel, 
set the IBR-ZREMOTE to this new keypad address and enroll the IBR-
ZREMOTE into your subscribers account.   
 

Alarm Reporting 

The IBR-ZREMOTE is also an Internet reporting module, capable of 
reporting alarms and events to any central station equipped with the Napco NetLink  NL-RCV-RMPCUL central station 
receiver or NetLink NL-CSRCV central station software application.  The IBR-ZREMOTE also permits high speed 
upload/download of the control panel through the Internet.  Refer to manuals WI1491 (NL-RCV-RMPCUL) and OI294 
(NL-CSRCV) for details. 
 

Overview:  Home Control Network  

A home control network is a system used for controlling lights, appliances, air conditioning, heating, burglary alarm 
systems and other devices within a home or office.  Z-Wave is a reliable and robust wireless home control network 
standard created by Zensys, Inc. (

www.zen-sys.com

), operating within an interconnected "mesh" network where at least 

two pathways exist for each device (thus if one pathway fails, another is still available).  In addition, Z-Wave devices 
operate within the 902-928 MHz band, and therefore will not interfere with Wi-Fi and other devices using the 2.4 GHz 
band. 
The simplest Z-Wave network consists of a primary "controller" and single controllable device or "node" such as a light 
switch, thermostat, etc.  Additional controllers and devices can be "included" into (or "excluded" from) the network at any 

 

KEYPAD BUS

 

BROADBAND 

MODEM

 

TO PANEL SERIAL PORT 

(only needed for NL-MOD 
CS communication)

 

 

CONTROL 

PANEL

 

KEYPAD

 

IBR-ZREMOTE

 

ISEE-WAP 

(

(

(

 

(

(

(

 

(1) C

A

T

5 Netw

ork 

Connection

 

(2) CAT5 Network 

Connection 

(3) CAT5 to Router 

ROUTER 

 

Summary of Contents for iBridge Suite

Page 1: ...00 645 9445 For Technical Service 800 645 9440 or visit us at http tech napcosecurity com Note Technical Service is for security professionals only Publicly traded on NASDAQ Symbol NSSC NAPCO 2015 Z R...

Page 2: ...o to www ibridgeonline com to access your existing account or register for a new account Device apps are available for iPhones iPads and Android devices from their respective apps markets Remote Contr...

Page 3: ...the iBridge mobile app using the iBridge Wi Fi service provided by the IBR WIFI MOD NOTE A remote service subscriber account on www ibridgeonline com is NOT required for LOCAL ONLY control For remote...

Page 4: ...ess to the IBR ZREMOTE and the TCP IP network and also provides Wi Fi for local control using the iBridge mobile app running on iPhones iPads or Android devices The ISEE WAP is not required if not usi...

Page 5: ...nd mount the charging plate as described in WI1944 or just connect the power adapter to the charger plate observing polarity and power the IBR ITAB to continue STEP 2 CONFIGURE THE CONTROL PANEL The a...

Page 6: ...eypad Assignment select the keypad address you will set up in step 5 for the IBR ZREMOTE and change the keypad address Type to RCM and add the keypad into the Area see image at right select EZ Arm 6 c...

Page 7: ...g a configuration keypad such as a Napco GEM RP1CAe2 or GEM K1CA to configure the IBR ZREMOTE recommended method Using an app on your iPhone iPad or Android device to configure the IBR ZREMOTE Using t...

Page 8: ...d select KEYPAD MODE After putting the control panel into Keypad Configuration Mode it normally takes up to 40 seconds for the keypad on the iBridge APP to go out of system The keypad will display 01...

Page 9: ...et to go out of system The keypad will display 01 Out of System RCM MODULE IMPORTANT After the display reads XX OUT OF SYSTEM you MUST stop and wait for the IBR ZREMOTE components to reset and prepare...

Page 10: ...n is now placed in the Please enter pass word popup as shown Tap OK The following warning popup appears Tap Yes and the following User Settings menu appears Tap Tablet then tap Connection The followin...

Page 11: ...onnect to the ISEE WAP with this unique SSID and this unique Key Proceed as follows Choose the Tablet Connection SSID At the Connection Settings menu that appears shown at right tap 2 Tablet Connectio...

Page 12: ...y IP address Tap to select each camera one at a time and tap Lock to lock the camera Exit when complete Lock Down the ISEE WAP In the Connection Settings menu tap 4 Lock Down IBRIDGE ISEE WAP Locking...

Page 13: ...connected with the correct ISEE WAP press the Back Power Button repeatedly until the Home Screen appears then press the Security button A screen with your arming choices ap pears Arm the system by fir...

Page 14: ...ew a list of User IDs as well as manage both your cameras and keypads registered to your dealer account Note For forgotten passwords your customer must click the Forgot your password link at www ibrid...

Page 15: ...1944 CONFIGURING THE IBR ITAB WI1944 The IBR ITAB Installation Mounting and Programming instructions describes how to physically install the IBR ITAB to the wall and also describes the three 3 types o...

Page 16: ...cient for the 380mA required for the IBR ITAB HW use a separate UL Listed Security and Signaling power limited 12V power supply Be sure the negative terminals of the power supply and control panel are...

Page 17: ...STANDARD KEYPAD Internet RED BLACK GREEN YELLOW IBR WIFI MOD CONTROL PANEL CAMERAS IBR ITAB IBR WIFI MOD Wireless Panel Interface communicates between Internet Gemini Control Panel through the 4 wire...

Page 18: ...18 NOTES...

Page 19: ...to a different outlet so that computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional sugges...

Page 20: ...on purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s...

Reviews: