SPECIFICATIONS
Coverage (l x w): 50' x 50' (15.2m x 15.2m) at 20°C (68°F),
typical. (with High Sensitivity Jumper “SEN”
installed)
30' x 35' (9.1m x 10.6m) at 20°C (68°F),
typical. (with Normal Sensitivity)
Operating Temperature: -10° to +50°C (14°F to 122°F)
Mounting: Wall or corner, 6.5’ to 8.5' max.
Alarm Output: Normally-Closed Form-A Relay
Contact Ratings: 100mA, 24VDC with internal 10 Ohm current-
limiting resistor
POWER-SUPPLY REQUIREMENTS
Note: This unit is intended for operation from a power source that
provides a 4 hour battery backup in the event of a power failure.
Filtered Dc: 10.6 to 16V DC nominal with battery backup from
control panel.
Current Drain: 28mA (idle or alarm) at 12VDC (nominal) 33mA
(idle or alarm) at 16VDC (nominal).
PHYSICAL
Dimensions: 4.5 in x 2.5 in x 1.8 in (HxWxD)
Shipping Weight: 6 oz.
3
Summary of Contents for IQ PROFILER -
Page 14: ...14...