Your alarm specialist may have 

programmed your system to be 

monitored by a central station.  The Go-

Anywhere Hub has a built-in radio / Inter-

net communicator that can transmit 

emergency signals and status reports to 

the central station 24 hours a day. 

 

Communicator Features 

Abort Delay.

 Ask your installer 

which of your zones have Abort De-

lay, a delay that enables you to reset 

the system before it communicates to 

the central station.  Your system has 

a SIA CP-01 required Abort Delay of 

30 seconds (it may be removed or 

increased up to 45 seconds, at your 

option, by consulting with your install-

er). 

Regular Burglary 

(Non-24-Hour) 

Zone reports are aborted by 

disarming within the delay period. 

24-Hour Zones 

and zones 

programmed to report restores must 

be restored first, then the Go-

Anywhere Hub armed and disarmed, 

all within the delay period. 

Opening and/or Closing 

Reporting.  

Your system can notify 

the central station every time it is 

disarmed or armed.  Any or all of up to 

96 different users can each be identified.  

If your system reports on arming (Closing 

Report), the central station will 

acknowledge arming.  This will signal at 

the keypad as a "ringback" beep.  

Note:

 

If the ringback signal is not heard, call for 

service. 

C E N T R A L   S T A T I O N   M O N I T O R I N G  

 

EMERGENCY SERVICES  

NOTIFIED UPON ALARM CONDITION 

EMERGENCY 

SERVICE 

DISPATCH 

(MONITORS 

YOUR SYSTEM 

24 HOURS A 

DAY) 

PROTECTED PREMISES 

PROTECTED PREMISES 

RADIO and/or INTERNET 

COMMUNICATOR 

RADIO and/or INTERNET 

COMMUNICATOR 

CENTRAL STATION 

 

 

Summary of Contents for iSecure ISEC-WL-KEYPAD

Page 1: ...1 NAPCO 2019 OI400LF 12 19...

Page 2: ...lar needs Regardless of how your system has been configured rest assured that it has been carefully designed and engineered to the highest industry standards To assure optimum safety and security fami...

Page 3: ...CO LIMITED WARRANTY 28 TO SILENCE AN ALARM PRESS YOUR CODE AND PRESS ENTER FOR SERVICE CALL __________________ CENTRAL STATION __________________ EXIT DELAY ________________________ ENTRY DELAY ______...

Page 4: ...4 14 13 12 11 10 9 8 6 5 4 3 2 KEYPAD CONTROLS INDICATORS 1 7...

Page 5: ...other Areas and is used with Emergency Buttons described above 10 AWAY Button 1 Arms all zones in the system 2 Scrolls Window display backward 3 Answers NO to questions in the Window display 11 STAY...

Page 6: ...s IP Network Wi Fi Yellow OFF Network OK Rapid Flashes No IP connection 1 blink No network cable detected 2 blinks No access to Internet via network cable 3 blinks Ethernet failed to com municate 4 bl...

Page 7: ...a voice prompt will inform you of the invalid code Re enter your User Code 3 Leave the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the syst...

Page 8: ...partitioned into multiple Areas one or more Areas may be armed while others remain disarmed Change Area Allows you to arm disarm other Areas in a partitioned system To arm a different Area 1 Press the...

Page 9: ...S lights will turn on and the words STAY and ARMED will appear on the keypad display indicating that it is safe to move within the premises If you arm AWAY do not exit and the system automatically rev...

Page 10: ...police emergency Police Emergency programmed YES NO Easy Exit Your system has been programmed for Easy Exit which allows you to exit the premises while the system is armed STAY By activating Easy Exi...

Page 11: ...s from a neighbor s telephone To silence an audible alarm 1 Enter your User Code and press ENTER After the system is disarmed the Window will continue to display the number s of the zone s violated 2...

Page 12: ...de and press ENTER to silence the alarm Check the smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down sm...

Page 13: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Page 14: ...14 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 15: ...etect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detec...

Page 16: ...l operating mode if no activity is detected for longer than one minute 2 Display Zones Bypassed Displays bypassed zones Press STAY and AWAY to scroll bypassed zones 3 Activate Bell Test Activates the...

Page 17: ...are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the Go Anywhere Hub armed and disarmed all within the delay period O...

Page 18: ...Press 5 ENTER If LE appears Level enabled the threshold is ena bled to disable press ENTER Ld will appear If Ld appears Level disabled the threshold is disa bled to enable press ENTER LE will appear...

Page 19: ...y Backup power source in the Go Anywhere Hub enclosure to provide protection in the event of a power failure BYPASS Button Enables you to manually remove one or more protective zones from the system C...

Page 20: ...g e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected in the system Trouble A zone fault For example an open do...

Page 21: ...wise call installing company for service E02 Low Battery If there has been a recent power fail ure the battery may be partially de pleted and must be recharged by the Go Anywhere Smart Hub The Go Anyw...

Page 22: ...type as specified above Use of other types may pre sent a risk of fire or explosion Never recharge or disassemble a battery or dispose of in fire E06 NN Receiver Response Failure Call installing comp...

Page 23: ...ated has failed its automatic self test routine Call installing company for service E41 NNN Fire Trouble A problem has been detected on the fire zone indicated Call installing company for service E42...

Page 24: ...ses immediately If necessary call the Fire Department from an outside telephone If there is no evidence of a fire enter your User Code and press EN TER to silence the alarm Note the number of the Zone...

Page 25: ...ments install a second battery of the same type into the right side battery holder Important When installing two batteries ALWAYS install two FRESH batteries do not install a fresh second battery afte...

Page 26: ...26 NOTES...

Page 27: ...27 NOTES...

Page 28: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may...

Reviews: