Napco iSecure Security System
All technical manuals are available in PDF format at
tech.napcosecurity.com
35
12. Install Takeover Module (cont'd)
(+)
RED
12VDC
Back Up
Battery
(
–
)
BLACK
EARTH
GROUND
OPTIONAL
THERMOSTAT
(
–
)
(+)
4 WIRE
SMOKE
DETECTOR
*If the power to the CO
detector requires monitoring,
use a power monitoring relay
or other approved device.
(E)
2.2K
EOLR (part #
FT2200)
(
–
) (+)
FIRE
ZONE
IN
FIRE
ZONE
OUT
POWER
OUT
POWER
IN
Wiring example of a
Conventional 4
-
Wire
Smoke Detector
Wiring example of a
Carbon Monoxide
Detector
(
–
) (+)
POWER
IN*
EOLR
2.2K
Wiring example of a burglary
device; in this example, a
wired door / window contact
EOLR
2.2K
SET
JUMPER:
ZONE
1
FIRE
CO
BURG
SET
JUMPER:
ZONE
7
FIRE
CO
BURG
SET
JUMPER:
ZONE
8
FIRE
CO
BURG
P2
1 2 3 4 5 6
BAT
[
‒
]
BAT
[
+
]
DC
[
‒
]
DC
[
+
]
12-18VAC
TRANSFORMER
Control panel power or
auxiliary power supply
FIRE
CO
BURG
ZONE
8
ZONE
1
ZONE 2
ZONE
3
ZONE
4
ZONE
5
ZONE
6
ZONE
7
JP5
JP6
JP7
JP8
JP9
JP10
JP11
JP12
Zone Jumper
s
ISEC
-
WL
-
MODULE
Wiring Diagram
EARTH
+12V GND
‒
Z1+ Z2+ GND
‒
Z3+ Z4+ GND
‒
Z5+ Z6+ GND
‒
Z7+ Z8+ GND
‒
BATT+ PNL+
Some PCBs
m
ay
read "
AC
" &
"
AC
"
or
"
ACL
" &
"
ACN
"
16VAC SUPV
F PWR
Battery used by
the control
panel to be
"taken over"
2.2KΩ
(Co
ntr
ol
p
ane
l e
nc
lo
sur
e)
See
JUMPER DESCRIPTIONS
,
Jumper Block P2
on page 34.
1
- Shunt to factory
DEFAULT
flash
memory (enters RF LEARN mode).
2
- Shunt to
DISABLE AC
monitoring.
3
- Shunt to
DISABLE BATTERY
monitoring.
4
- Reserved.
5
- Reserved.
6
- Shunt to start an
END OF LINE
RESISTOR LEARN
process for
zone terminals
Z1
through
Z8
.