Napco iSecure Security System
All technical manuals are available in PDF format at
tech.napcosecurity.com
61
Cold Start, Test and Reset Processes
Your iSecure Go
-
Anywhere Smart Hub and 900 MHz Keypads, Siren and Take Over module can be reset back to their original
"default" conditions, i.e. the state each was in when they first left the factory. Proceed as follows:
Go
-
Anywhere Hub Factory Reset (Cold Start)
The Go
-
Anywhere Smart Hub can be reset back to its original "default" condition, clearing all programming and settings, including all
zones and keypads, and re
-
loading its factory default program.
1.
Remove AC power from the Go
-
Anywhere Hub.
2.
Separate the Go
-
Anywhere Hub front and rear housing by pushing in the two tabs at the bottom with a flat head screwdriver until
the tabs unhook. Battery power is removed upon separation of the housing.
3.
Add a jumper to the two (2) pins of
JP2
(located at the top left of the PC board).
4.
Re
-
connect AC power.
5.
Wait 60 seconds, or until error code
E09
-
00
appears on the keypad or touchpad display.
6.
Remove jumper from
JP2
.
7.
Reassemble the front and rear housing and re
-
connect AC power.
8.
Perform a Full Download of the Hub programming.
ISEC
-
WL
-
SIREN Factory Reset
Reference the four ISEC
-
WL
-
SIREN jumper positions shown at right. Orient the unit
with the wall outlet AC prongs at the top (as shown in the image).
Note:
Never use the
jumper position
N/A
.
Do not apply AC power when rear cover is open!
1.
Remove power.
2.
Remove jumper from pins (if necessary) and place jumper in "
Reset
" position.
3.
Wait 10 seconds, then install batteries*, observing polarity. The siren strobe will
flash 3 times.
4.
Remove jumper and place in "
Store
" position.
If the default process is successful, upon power up the LED will blink three times. If unsuc-
cessful, the LED will blink only once.
ISEC
-
WL
-
SIREN Strobe/Sounder Test
Reference the four ISEC
-
WL
-
SIREN jumper positions shown at right. Orient the unit with the
wall outlet AC prongs at the top (as shown in the image).
Note:
Never use the jumper position
N/A
. Use hearing protection (siren is rated at 85dBA).
Do not apply AC power when rear
cover is open!
1.
Remove AC and batteries*.
2.
Remove jumper from pins (if necessary) and place jumper in "
Test
" position.
3.
Install batteries, observing polarity.
Upon the insertion of the 4th battery, the siren will sound
and the strobe will flash CONTINUOUSLY until shunt is returned to "
Store
" and batteries are
removed (in steps that follow).
4.
Remove jumper and place in "
Store
" position.
5.
Remove batteries to silence; replace batteries and restore AC (if necessary).
Do not apply
AC power when rear cover is open!
ISEC
-
WL
-
MODULE
Takeover Module
Factory Reset
1.
Remove power.
2.
Place jumper on
J1
.
3.
Power up the module.
4.
Wait 10 seconds and remove jumper from
J1
.
If the default process is successful, upon power up the LED will slowly blink.
ISEC
-
WL
-
KEYPAD
Wireless Battery
-
Powered Standard Keypad
Factory Reset*
1.
Press and hold the
AREA
(
) button until "
LF"
appears in the display.
2.
Press
0
,
2
,
ENTER
.
If the default process is successful, the "dot" in the left bottom corner of the display and the word
READY
will appear. If unsuc-
cessful, only the "dot" in the left bottom corner of the display will appear.
Note:
This reset procedure can only be initiated either
within 1 minute after power up, or when the keypad flashes "o#" (where # is the keypad address).
ISEC
-
WL
-
TOUCH
Wireless 4.3" Full Color Security Touchscreen Keypad
Factory Reset
1.
From the Home screen, press the
System Settings
("gears") icon (shown at right).
2.
Enter the Master Security Code (refer to the OI404LF card; see page 7 for details), then press
ENTER
.
3.
In the
System Settings
screen that opens, press the
Dealer KP Config
button.
4.
Press the
LearnOff
button. The
LearnStatus
will change from
ON
to
OFF
.
5.
Press
Exit
twice to save and exit.
Note:
To verify the
LearnStatus
, re
-
enter the
System Settings
screen and press the
Dealer KP Config
button.
System Settings
("gears") icon
Location of ISEC
-
WL
-
SIREN
Jumper Pins for:
•
Factory Reset
•
Strobe / Sounder Test
2 1
Test
2 1
Store
2 1
Reset
2 1
(
N/A
)
2 1
*With battery powered devices, always remove batteries if storing for extended periods.