LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 32
ZONE OPTIONS - ZONES 17 TO 32 (ADDRESS 1029-1144)
ZONES 17
→
24
ZONES 25
→
32
ZONE FEATURES
ADDR Z17 Z18 Z19 Z20 Z21 Z22 Z23 Z24 ADDR Z25 Z26 Z27 Z28 Z29 Z30 Z31 Z32
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Priority
1029
1093
Priority with Bypass
1030
1094
Auto-Bypass
1031
1095
Selective Bypass
1032
1096
Keyswitch Arming
1033
1097
Auto-Bypass Re-entry
1034
1098
Pre-Alarm Warning
1035
1099
Never Arm
1036
1100
24-Hour Zone
1037
1101
Alarm Output
1038
1102
Pulsed Alarm Output
1039
1103
PGM1 Output
1040
1104
PGM2 Output
1041
1105
Entry/Exit 1
1042
1106
Entry/Exit 2
1043
1107
Exit/Entry Follower
1044
1108
Auto Reset
1045
1109
Swinger Shutdown
1046
1110
Chime
1047
1111
Abort Delay
1048
1112
Power-up Delay
1049
1113
Day Zone Open
1050
1114
Day Zone Short
1051
1115
Alarm on Day Zone
1052
1116
Alarm Telco 1
1053
1117
Alarm Restore 1
1054
1118
Trouble Telco 1
1055
1119
Trouble Restore 1
1056
1120
Alarm Telco 3
1057
1121
Alarm Restore 3
1058
1122
Trouble Telco 3
1059
1123
Trouble Restore 3
1060
1124
No EOL Resistor
1061
1125
Trouble on Open
1062
1126
Trouble on Short
1063
1127
Zone Area 1
1064
1128
Zone Area 2
1065
1129
Interior (Stay) Bypass
1068
1132
Keypad Sounder on Alarm
1069
1133
Fire
1071
1135
Fire Alarm Verification
1072
1136
Zone ANDing Group 1
1074
1138
Zone ANDing Group 2
1075
1139
Zone ANDing Group 3
1076
1140
Zone ANDing Group 4
1077
1141
Sensor Watch
1078
1142
RESERVED
1079
1143
Chime 2
1080
1144
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer YES (
p
) in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer YES (
p
) in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
Zone Area 3
1066
1130
Zone Area 4
1067
1131
DEFAULTS:
The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
Priority, Selective By-
pass, Alarm Output, Auto Reset, Swinger Shutdown
and
Zone Area 1
are enabled for the total number of zones entered in "
#
OF ZONES IN AREA1 ENTER # ZONES
".
Alarm Telco 1
is enabled for the zone number(s) entered in "
REPORT ALL ZONES TO CENTRAL ZONES?
Y/N
".
Entry/Exit 1
and
Chime
are enabled for the zone number(s) entered in "
ENTRY/EXIT ZONES ENTER ZONE #
".
Exit/Entry Follower
and
Interior Bypass
are enabled for the zone number(s) entered in "
INTERIOR ZONES ENTER ZONE #
".
Pulse Alarm Output
is enabled
for the zone number(s) entered in "
FIRE ZONES ENTER ZONE #
".
Fire
is enabled for the zone number(s) entered in "
FIRE ZONES ENTER
ZONE #
".