ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions
15C. INSTALL RECTANGULAR PROXIMITY READER COVER
The
Rectangular Proximity Reader
cover "snaps" into place, as follows:
a. Hook
the
Rectangular Proximity Reader
on the two
Top Tabs
on the top of
the
Rectangular Mounting Plate
(see Fig 15C).
b. Press firmly on the bottom of the
Rectangular Proximity
Reader
until it " snaps" into place.
Be careful not to pinch any wires.
16. INSTALL "CONTROL UNIT MOUNTING PLATE"
Locate the two pilot holes for the
Control Unit Mounting Plate
mounting screws
that were drilled into the inside ("protected") door surface in step 9B.
Important!
See Fig 16 to determine which end is the " TOP" .
Place
the
Control Unit Mounting Plate
against the inside ("protected" side) door
surface and secure using the two Phillips Flat Head screws appropriate for the
door type as follows:
For Metal Doors:
#6-32 x 5/8" long Type 23 thread
cutting Phillips Flat head, U-cut (part #SC682);
For Wood Doors:
#6 x 3/4" long undercut self-
tapping Type A (part #SC596)
FIG. 15CC
FIG. 15C
FIG. 16:
CONTROL UNIT MOUNTING
PLATE
(TOP)
(BOTTOM)