3. TAPE ON DOOR: "PROXIMITY READER" TEMPLATE (USE WI2102
FOR SOLID WOOD DOORS, OR USE WI2154 FOR FIRE RATED MET-
AL DOORS)
Remember,
the
Proximity Reader
is always located on the outside
("unprotected" side) door surface.
Fold and place the template on the
outside door edge
(see arrow in Fig. 3
for an example). Align the template with the "
HORIZONTAL CENTER
LINE OF LEVER
" as shown on the template. Tape the template in place.
IMPORTANT:
For installation on UL Listed Wood Fire Doors fill the
through hole wire passage with UL Classified Fire Stop Sealant after con-
necting all wiring and testing the Lock.
4. MARK TEMPLATE "PROXIMITY READER" HOLES
On the outside door surface, mark the two holes for the
Proximity Reader
mounting screws.
Mark the center of this wire passage hole (used for the
Mortise Lock Motor Wire
,
Proximity Reader
and
Door Contact
Sensor
wires). Do NOT remove the template yet.
Note:
This hole is a
5/8" Diameter Thru-Hole
for wood doors
(template WI2102) and a
1/2" Diameter NON-Thru-Hole
for fire rated metal doors (template WI2154).
TIP:
Take special notice of this hole, as it is an essential hole for this installation and is referenced several
times throughout these instructions.
FIG. 4. USE THE CORRECT TEMPLATE FOR DOOR TYPE!
(WI2102 SHOWN ABOVE LEFT FOR SOLID WOOD DOORS, OR WI2154 SHOWN ABOVE RIGHT FOR FIRE RATED METAL DOORS)
FIG. 3: EXAMPLE OF OUTSIDE DOOR
EDGE (ARROW)
WOOD DOORS
METAL DOORS