ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions
6
DOOR PREP: DRILL HOLES
IMPORTANT:
Remove all burrs from wire holes.
Sharp edges can eventually wear away wire insulation
.
9. DRILL THE FOLLOWING HOLES IN THE DOOR
9A.
Use
7/64"
drill bit:
On the outside ("unprotected side")
door surface, drill the two pilot
holes for the
Proximity Reader
mounting screws (NOT thru-holes,
drill only into the door surface).
9B.
Use
7/64"
drill bit:
On the inside ("protected side")
door surface, drill the two pilot
holes for the
Control Unit Mounting
Plate
mounting screws (NOT
thru-holes). Drill only into the in-
side door surface.
9C. IMPORTANT:
This hole is a
5/8" diameter thru-hole for
wood doors (template WI2102)
and a 1/2" diameter offset NON
-thru-hole for fire rated metal
doors (template WI2154).
9D.
Use
3/4"
drill bit: 3/4"
Door Contact
Sensor
hole in edge of the door
(for solid wood doors, drill until the
hole intersects with the
5/8" Diameter
Thru-Hole
).
FIG. 9A: 7/64" PILOT HOLE ON OUT-
SIDE DOOR SURFACE FOR
PROXIMITY READER
(5/8" DIAMETER
THRU-HOLE,
DRILLED IN
STEP 9C)
"DOOR CONTACT SENSOR" HOLE
(3/4") IN EDGE OF DOOR
FIG. 9D: 3/4" DOOR CONTACT SENSOR HOLE IN EDGE OF THE DOOR
FIG. 9B: 7/64" PILOT HOLE
ON INSIDE DOOR SURFACE
FOR CONTROL UNIT PLATE
FIG. 9C: HOLE SIZE/LOCATION DEPENDS ON DOOR TYPE
WOOD DOORS
METAL DOORS