 The 

J

 and 

T

 "style" ArchiTech series locks contain Bluetooth LE technology that allows for entry via a smartphone 

application ("app").  The iLock smartphone app works essentially as any other type of proximity credential; simply 
launch the iLock app and tap the 

Unlock 

button to allow entry.  For added security, an optional password can be set 

in the iLock app that would then be required for every unlock request.  

Note: 

 Up to 27 Bluetooth Users are support-

ed for any one ArchiTech series lock.   

 

Downloading the iLock App 



For iPhone Users:

  Go to your iTunes store, search for " iLock"  and download the app.   



For Android Users:

  Go to your Google Play store, search for " iLock"  and download the app.  

 

 

Note: 

 The following special permissions are required:   



Device Location 



File Access.   

 

Enrolling Bluetooth Credentials 

 

After the iLock app has been downloaded and installed on your smartphone: 

 

1.  Run the iLock app and the 

Settings 

screen opens.   

 

2.  Place the ArchiTech series lock into Enroll Mode by pressing the "

Program / Passage

" button once (Enroll Mode 

= continuous beeping with green LED flashes).   

 

  Depending on the programming "environment" of the lock (see page 9), Enroll Mode is entered as follows: 



Initial lock startup

:  Simply press the "

Program / Passage

"  button once 



Program Card Programming

:  Present a " Program Card"  

and with the state of the lock " unlocked"

press the "

Program / Passage

" button once 



DL-Windows Mode

:  Present a " Program Card"  OR any Administrative User (2-11); 

with the state of the 

lock "unlocked", 

press "

Program / Passage

" button once 

 

3.  Within 30 seconds, tap "

Add a New Lock

" on the iLock app.   

 

4. In the 

Select Lock 

screen, select the lock that displays the device name of "

MyLock

".  Lock acknowledges with 

two beeps. 

 

5.  Within 120 seconds, enter a 

Lock Name 

and password (maximum 20 alphanumeric characters).   



Successful Pairing:

  Lock sounds 4 beeps with 4 green LED flashes  



Unsuccessful Pairing:

  Lock sounds 7 beeps with 7 red LED flashes. 

 

6. 

Exit Enroll Mode:

  Press and firmly hold the "

Program / Passage

"  button for 4 seconds until you hear a 

series of beeps.   

 

 

Follow the above steps for each additional Bluetooth credential.   

 
 

Bluetooth Credential Considerations 



If Bluetooth credentials were created / enrolled using "Program Card Programming" prior to integration with DL-
Windows, the Bluetooth credentials will NOT be overwritten and will remain in the lock memory.   



Bluetooth credentials are added to slots 7000 through 7089*, and are logged accordingly.   



The first two Bluetooth credentials added (slots 7000, 7001) have the same functionality as Administrative Users 
(credentials added to any of the slots numbered 2 through 11 in DL-Windows).  Therefore, the first two Bluetooth 
Users have the ability to add additional Bluetooth credentials.  See the "

ArchiTech User Number Definitions

" chart 

on page 7.   

Bluetooth Support 

*The latest firmware has an expanded Bluetooth capacity, with credentials added to slots 7000 through 7089.  Please note that this high number, which 

indicates the maximum number of Bluetooth users, will vary depending on the firmware installed. 

Summary of Contents for Networx ArchiTech

Page 1: ...RD DL WINDOWS PROGRAMMING SOFTWARE ArchiTech by Networx with Keypad ProxReader USER S GUIDE NAPCO Security Technologies Inc 2018 OI410LF 8 18 RR 1BUTTON WIRELESS REMOTE RELEASE AL PRE PROXIMITY CREDEN...

Page 2: ...t Program Card Programming Operation 11 12 Keypad Programming Overview of Functions 13 Keypad Programming Conventions 14 Keypad Programming Functions 14 25 Keypad Programming Record Sheet 26 Keypad Pr...

Page 3: ...ability see Features Screen in OI382 Up loadable using Alarm Lock s DL Windows Software see OI382 and OI383 Lock Features Metal Key Override for all cylindrical locks Non Volatile Fixed Memory Real Ti...

Page 4: ...nd consequently can control the devices in the system Note Version 2 Gateways are the second generation of Networx wireless Gateways ArchiTech door locks are still compatible with Version 1 Gateways S...

Page 5: ...1 PM and lock again at 5 PM every week Terminology Used in this Manual day See next page for the definition of Group In DL Windows use the Schedule TimeZone screen to first create an individual block...

Page 6: ...ystem can be used to disseminate these com mands to all locks in the network Who are Users 297 300 Credentials assigned to User Numbers 297 298 299 and 300 have special abilities as follows Terminolog...

Page 7: ...ministrative Users Programming ability able to place lock into Enroll Mode and to enroll additional Basic User credentials or a Wireless Remote Release Emergency User during an Emergency state credent...

Page 8: ...Door Contact Sensor The Door Contact Sensor is required to monitor the position of the door open or closed The Door Contact Sensor is shown above at right note also that a Sensor is integrated within...

Page 9: ...Program Mode and make changes to the lock programming Once the new Master Code is set then you can program other things using the keypad such as setting the weekday date and time After this you can s...

Page 10: ...use the keypad to perform all of the steps on this page below Enter Program Mode and Change Factory Master Code 1 Press the default Master Code 1 2 3 4 5 6 2 Wait for the green light and press and hol...

Page 11: ...2 short confirmation beeps 3 Present the second proximity card to the Proximity Reader Again listen for 2 short confirmation beeps If the second card is not enrolled within the 30 second time out sim...

Page 12: ...d the Program Passage button for 4 seconds until you hear a series of beeps Exit Enroll Mode indication All added credentials are considered Basic Users i e no programming abilities cannot enter Enrol...

Page 13: ...nction 45 46 Passage Mode Enable Disable See page 19 Function 47 Reserved Keypad Programming Overview of Functions Function 48 Enable Passage Mode See page 20 Function 49 Disable Passage Mode See page...

Page 14: ...edential to reader within 10 seconds User Number Entering a User Code PIN No Code into the lock programming Programming Key Sequence Programming Information General Program Mode Information If a wrong...

Page 15: ...amples regarding special Users 297 300 9 9 Enable User 300 Service Code 1 0 0 0 0 10 Erase All Users Except the Master Code User 1 This Function enabled through keypad only Erases all User Codes excep...

Page 16: ...Function only disables the timeout the event associated with the timeout will remain 3 CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will eac...

Page 17: ...Group associations for User 67 Enter 3 5 6 7 NOTE If a User is associated with more than one Group all associated Groups would have to be disabled before the User is disabled 3 36 Reserved Clear All...

Page 18: ...nds at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default...

Page 19: ...al 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of ze...

Page 20: ...he Pass Time expires the lock will re lock automati cally Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Note Compare to Function 55 Enab...

Page 21: ...of the default program Remote Input Wireless Remote Release Pairing 6 5 65 Enable Remote Input 2 REMOTE INPUT 6 5 ____ Slot Number 1 10 65 Pair Wireless Remote Release Note In addition to using a wire...

Page 22: ...n programmed a Group 3 User is allowed entry only once then be comes disabled Note When the credential is entered for the first time and access is granted the Event Log will show Entry followed by Use...

Page 23: ...be set ON to enable Forced Door Detection 56 Automatic Deadbolt No Passage Override Enable when automatic deadbolt hardware is used Note Be aware of the following terminology when reading the descript...

Page 24: ...ll go into a locked state Presumably the user will be inside the premises but does not need to be if the user chooses to remain outside the premises during the second deadbolt extension a valid creden...

Page 25: ...ay 6 for Friday 7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week 3 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage M...

Page 26: ...eet 24 One Time Entry for Group 3 Users 25 Disable Sounder 29 Toggle Passage Mode 36 Cancel Passage on Button Press 38 Lock Responds to Global Emergency Commands 39 Users are Disabled During Lockdown...

Page 27: ...ogrammed For the Day enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour form...

Page 28: ...ID card An example N95I2 Lock Type selection is shown below Note Correct Lock Types are required for successful ly linking a physical lock to the DL Windows Lock Pro file see What is a Lock Program o...

Page 29: ...ress etc will be sustained indefinitely until cancelled via a lock Schedule or subsequent Program Passage button press Enable One Time Entry option Used with the above described Automatic Deadbolt fun...

Page 30: ...ies lock is installed inside a business office where the office closes and remains empty at night a Schedule can be created to place the ArchiTech series lock into a Power Saving Mode from 5 05 PM thr...

Page 31: ...he documentation that came with it and also the Wireless Remote Releases section on page 36 Receiving Emergency Commands Lock Responds to Global Emergency Com mands When enabled The lock WILL accept a...

Page 32: ...ers in DL Windows for more information about adding Emergency Users in DL Windows see OI383 Note All paired Wireless Remote Releases have the ability to initiate Emergen cy Commands see page 36 for mo...

Page 33: ...Card OR any Administrative User 2 11 with the state of the lock unlocked press Program Passage button once 3 Within 30 seconds tap Add a New Lock on the iLock app 4 In the Select Lock screen select th...

Page 34: ...page 7 Battery Indicates the latest percentage of remaining usable ca pacity of the battery in the selected lock updated upon each successful communication Important The per centage will equal zero up...

Page 35: ...series lock The lock will unlock within a few seconds this time varies with smartphone models Red padlock turns green upon unlock and remains green unlocked for the duration of the programmed Pass Ti...

Page 36: ...Wireless Remote Release button you wish to pair Selecting a button in advance will greatly assist this process Keep the Wireless Remote Release in your hand as you perform the next steps 2 Place the A...

Page 37: ...n the Finishing Plate to its original location and secure with the two 8 32 x 1 4 Phillips Flat Head screws To replace batteries in the Surface Mounted Networx Control Unit 1 Using the supplied Allen...

Page 38: ...nted Networx Control Unit 1 Using the supplied Allen key remove the mounting screw located in the previous step 6 32 Allen Head coun tersunk U cut Dog Point screw part SC681 shown at right Put screw a...

Page 39: ...l Unit installed however DO NOT touch the Program Passage button AT ANY TIME during the procedure If the lock is powered down for an extended period of time and if you do not hear 3 beeps when power i...

Page 40: ...exit Sounder ca dence longer for exiting Enroll Mode compared with entering Waiting for credential in Enroll Mode Rapid Green for 25 seconds then Red for final 5 seconds Rapid beeps for entire 30 seco...

Page 41: ...41 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______...

Page 42: ...tory condition when the device was first taken out of its box With an ArchiTech lock its default settings are per manently encoded within the lock s fixed memory and when the lock is first started or...

Page 43: ...of time PROGRAM CARDS Used with Program Card Programming operation two ordinary proximity cards are made into Program Cards permit ting all programming to be performed at the lock s Proximity Reader...

Page 44: ...ducts In no event shall NAPCO be liable for an amount in ex cess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise a...

Reviews: