background image

14

WI1372  XP-600 Installation Instructions  

[15]Line Cut Time-to-Fail  

Enable this feature by programming the 
delay time required to declare a line cut 
failure.  Programming 000 will disable line 
cut detection. 
 

[16]Wireless Supervisory Timer 

A transmitter will send a transmission every 
time it is tripped; when there is no activity, 
the transmitter sends a supervisory 
transmission about once an hour.  If the 
receiver does not receive any signal (either 
a trip or a status) from a transmitter in the 
time specified, a system trouble ‘RF 
Supervisory Failure' will be indicated at the 
keypad.  Timer is programmable from 1-26 
hours; 0 means NO supervision.  

 

[17]Wireless Smoke Supervisory Timer 

A smoke detector will send a transmission 
every time it is tripped; when there is NO 
activity, the smoke detector sends a 
supervisory transmission about once an 
hour.  If the receiver does not receive a 
signal (either a trip or a status) from a 
transmitter in the time specified, a system 
trouble ‘RF Supervisory Failure' will be 
indicated at the keypad.  The Supervisory 
timer is programmable from 1-8 hours; 0 
means NO supervision.  
 

[18]Test Timer Offset  

Enter the time, in hours, that a Test Timer  
will be reported after Dealer Mode has been 
exited.  With the default value of 12,  the test 
timer will be sent 12 hours after exiting 
Dealer Mode.  The test timer can also be 
offset using NAPCO PCD3000 Downloading 
Software.  On power up the test timer is sent 
immediately.  Follow the commands below 
to offset the test timer using Quickloader 
Software: 

 
From the Status Screen  

Press 

F6 

Select 

M

iscellaneous Control 

Select 

T

est Timer Offset 

Enter New Test Timer Offset: 12 

hours 

Enter 

u

 to advance the test timer 

due in time by 12 hours. 

 

System Features 

 

[20]Keypad Features 1 

(1) Enable Keypad Fire 

(

ee

Additional Programming required: 
Select reporting to Telco 1 [36-1] or Telco 3 
[56-1]. 

(2) Enable Keypad AUX

 (

ff

Additional Programming required: 
Select reporting to Telco 1 [36-2] or Telco 3 
[56-2]. 

(3) Enable Keypad Panic

 (

gG

)  

Additional Programming required: 
Select reporting to Telco 1 [36-3] or Telco 3 
[56-3]. 
(

4) Enable Ambush -

 If enabled, the 6th 

User Code will send an Ambush report 
when entered to disarm the system.   
Additional Programming required: 
Program User 6 Arm/Disarm Code.   
Select reporting to Telco 1 [36-2] or Telco 3 
[56-2]. 

UL Installations:

  If Keypad Fire [20-1] is 

enabled, the keypad must be mounted 
within (3) three feet from the Control Panel. 

 

[21]Keypad Features 2 

(1) Audible Panic

 - Keypad Panic will not 

turn the Bell on unless this option is 
programmed. 

(2) Exit/Entry with Urgency

 - select to give 

an audible indication of Exit and Entry times.  
During the last 10 seconds of entry and exit 
time, the keypad sounds a distinct sound to 
indicate the premises must be left or the 
panel must be disarmed. 

(3) Display Bypassed (Armed)

 - Select to 

display bypassed zones while the panel is 
armed. 

(4) Disable Code Entry Beeps - 

Program 

to disable keypad beeping on valid code and 
function entries. 

Summary of Contents for RPXP6GT

Page 1: ...XP 600 RPXP6GT keypad Control Panel Communicator Installation Instructions WI1372 1 05 NAPCO 2005...

Page 2: ...Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 6 Users Opening after Alarm R...

Page 3: ...Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2...

Page 4: ...ss PIR Wireless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles in...

Page 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Page 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fir...

Page 7: ...mA Keypad Operation Keypad zone LEDs indicate zone status W ARMED X READY and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad So...

Page 8: ...y Follower Zones can be bypassed when the M or N keys on the Keyfob have been programmed for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the E...

Page 9: ...omatic Bypassing Home Away with Delay Zones From the Keypad Press C B to return protection to Home Away with Delay Zones that have been automatically bypassed Three minutes are allowed to walk through...

Page 10: ...rogram Mode press the b key XP 600 Commands User Commands A 1 Bell Test Enter this command to turn on the Bell keypad sounder and keypad LEDs for 2 seconds The battery is tested during a Bell Test and...

Page 11: ...ds when hardwired zones are faulted and for 1 second when zones are restored Wireless Operation Signal Strength While in Fault Find mode the keypad will provide an audible Table 6 and visual Figure 5...

Page 12: ...lows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay...

Page 13: ...it through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a val...

Page 14: ...000 Downloading Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quickloader Software From the Status Screen Press F6 Select Miscellaneo...

Page 15: ...armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 I Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a...

Page 16: ...orrect data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Han...

Page 17: ...icator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pu...

Page 18: ...st digit of the report code sent the second digit is the zone number of the reporting zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Cod...

Page 19: ...de 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing T...

Page 20: ...1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the M or N buttons on the Keyfob are pressed Additional programm...

Page 21: ...s 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the pan...

Page 22: ...ollowing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test performed every 4 hours instead of 2...

Page 23: ...e keypad will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The foll...

Page 24: ...A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 6 Wireles...

Page 25: ...flowing through the Bell circuit for supervision To eliminate the buzzing cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel...

Page 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Page 27: ...Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire 2 2K 2 2K Normally Open Zone Wiring Wire the normally open contact as shown Zone 4 Program t...

Page 28: ...Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expec...

Reviews: