WI1372  XP-600 Installation Instructions  

Keypad LEDs 

W

 ARMED

 

LED

 

DEFINITION

  

Armed                                       ON 
Instant Mode                            Rapid Flash 
Zone in Alarm                          Flashing 

 

X

 READY

 

LED

 

DEFINITION

  

Ready to be Armed                  ON 
Zone faulted                             OFF 

 

H

SYSTEM

 

LED

 

DEFINITION

 

AC Failure                                Flashing 
System Trouble(s)                   ON 

 

FIRE

 

LED

 

DEFINITION

          

Fire Alarm                                Flashing 
Fire Memory/*Fire Trbl             ON 
*See Note 1 
 

AC

 

LED

 

DEFINITION

            

AC Present                              ON 
AC Failure                                OFF 
 

ZONE

 

LED

 

DEFINITION

         

Faulted Zone                            ON 
Bypassed  Zone                       Slow  Flash 
Zone in Alarm                          Flashing 
 
 
 

Panel Operation 

 

Arming (System ON) 

Before arming the system close all protected 
zones (unless programmed as Auto-Bypass 
Reentry Zones).  Enter a 4-digit Arm/Disarm 
code, the keypad will provide a feedback beep 
for each key pressed.  If a valid Arm/Disarm 
code is entered, the keypad will beep 3 times.  If 
an incorrect Arm/Disarm code is entered, the 
keypad will sound a 1-second tone indicating an 
incorrect entry.  
 

Arming without Entry Delay (Instant 
Mode) 

Enter the 

A

 

1

 to eliminate the entry delay.  

The 

W

 ARMED LED will flash rapidly to indicate 

the panel is in Instant Mode.  If an Exit/Entry 
Zone is tripped while the panel is in Instant 
Mode the panel will go into alarm immediately. 
 

Arming/Disarming with a Keyfob  

The system can be armed by pressing the 

K

 

key, and disarmed by pressing the 

L

 key on 

the Keyfob.  Zones programmed as 

Exit/Entry 

Follower Zones

 can be bypassed when the 

M

 

or 

N

 keys on the Keyfob have been 

programmed for 

Interior

 

[81-84].  Zones 

programmed as Home

/Away with Delay Zones

 

can be armed regardless of the state of the 

Exit/

Entry Zones

 when the 

M

 or 

N

 keys on the 

Keyfob have been programmed for 

Full Set 

[81-

84].  To arm the system with all zones protected, 
press the 

K

 key.  Press and hold the 

M

 or 

N

 key for 1.5s to fully set the system (the LED 

on the Keyfob indicates the Keyfob has 
transmitted the signal).  Program 

Keyfob/

Keyswitch Chirp

 [23-4] for an audible indication 

of system arming and disarming. 

 

Arming/Disarming with a Keyswitch 

The system can be armed/disarmed by using a 
momentary Keyswitch wired to 

Zone 6

.  

Program 

Keyfob/Keyswitch Chirp

 [23-4] for an 

audible indication of system arming and 
disarming. 
 
 
 
 
 
 

 
Arming Instant with a Keyfob  

The panel can be ARMED INSTANT when the 

M

 or 

N

 keys on the Keyfob have been 

programmed for 

Instant 

[81-84].  To arm the 

system with Instant protection press the 

K

 

key, then press and hold the 

M

 or 

N

 key for 

1.5s to arm the panel with INSTANT protection.

 

 
Disarming (System OFF) 

After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry 

* If 

Fire Trouble on Fire LED

 [96-4] has been enabled, a steady 

Fire LED will indicate Fire Trouble.  

N

OTE

:

 

Faulted Keyswitch or silent 24 hour zone normally do not 
display at the keypad.  If a silent 24 hour zone or Keyswitch 
is faulted at the time of arming the faulted zone will display 
only while the priority sound is ON. 

N

OTE

:

 

Summary of Contents for RPXP6GT

Page 1: ...XP 600 RPXP6GT keypad Control Panel Communicator Installation Instructions WI1372 1 05 NAPCO 2005...

Page 2: ...Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 6 Users Opening after Alarm R...

Page 3: ...Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2...

Page 4: ...ss PIR Wireless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles in...

Page 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Page 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fir...

Page 7: ...mA Keypad Operation Keypad zone LEDs indicate zone status W ARMED X READY and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad So...

Page 8: ...y Follower Zones can be bypassed when the M or N keys on the Keyfob have been programmed for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the E...

Page 9: ...omatic Bypassing Home Away with Delay Zones From the Keypad Press C B to return protection to Home Away with Delay Zones that have been automatically bypassed Three minutes are allowed to walk through...

Page 10: ...rogram Mode press the b key XP 600 Commands User Commands A 1 Bell Test Enter this command to turn on the Bell keypad sounder and keypad LEDs for 2 seconds The battery is tested during a Bell Test and...

Page 11: ...ds when hardwired zones are faulted and for 1 second when zones are restored Wireless Operation Signal Strength While in Fault Find mode the keypad will provide an audible Table 6 and visual Figure 5...

Page 12: ...lows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay...

Page 13: ...it through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a val...

Page 14: ...000 Downloading Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quickloader Software From the Status Screen Press F6 Select Miscellaneo...

Page 15: ...armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 I Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a...

Page 16: ...orrect data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Han...

Page 17: ...icator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pu...

Page 18: ...st digit of the report code sent the second digit is the zone number of the reporting zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Cod...

Page 19: ...de 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing T...

Page 20: ...1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the M or N buttons on the Keyfob are pressed Additional programm...

Page 21: ...s 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the pan...

Page 22: ...ollowing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test performed every 4 hours instead of 2...

Page 23: ...e keypad will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The foll...

Page 24: ...A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 6 Wireles...

Page 25: ...flowing through the Bell circuit for supervision To eliminate the buzzing cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel...

Page 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Page 27: ...Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire 2 2K 2 2K Normally Open Zone Wiring Wire the normally open contact as shown Zone 4 Program t...

Page 28: ...Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expec...

Reviews: