26
W415-0762 / A / 07.19.10
8.0 MAINTENANCE
Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for
cleaning is established. If accumulation is excessive, disconnect the appliance and clean both the chimney and
the appliance. You may want to call a professional chimney sweep to clean them. Both have to be cleaned at
least once a year or as often as necessary.
Remove fi bre baffl es and clean above them once a year. Replace any broken bricks.
8.1 ASH REMOVAL PROCEDURES
Allow the ashes in your fi rebox to accumulate to a depth of two or three inches; they tend to burn themselves
up. When the fi re has burned down and cooled, remove any excess ashes but leave an ash bed approximately
1 inch deep on the fi rebox bottom to help maintain a hot charcoal bed.
NOTE: Optional ash pans are not equipped with a cover or rear folding handle.
A.
To remove the ashes, clear the ash away from the ash plug.
B.
Remove the ash plug. It is recommended to use a poker.
C.
Rake the excess ash into the ash drawer. Do not overfi ll the ash drawer. Ash should not accumulate
higher than the sides of the drawer.
D.
Before removing the drawer, ensure that the area around the ash opening is clean. Tap the ash from
the chute into the drawer, then place the ash plug back over opening.
8.2 CREOSOTE FORMATION AND REMOVAL
8.1.1 APPLIANCES WITHOUT ASH PAN
Since some models will not have ash pans, shovel some ashes out through the door into a metal container
with a tight fi tting lid. The ashes should be retained in the closed container until all cinders have thoroughly
cooled. Cold wood ashes can be used on the garden or in the compost.
8.1.2 APPLIANCES WITH ASH PAN
!
WARNING
TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
IMPROPER DISPOSAL OF ASHES RESULT IN FIRES. DO NOT DISCARD ASHES IN CARDBOARD
BOXES, DUMP IN BACK YARDS, OR STORE IN GARAGES.
IF USING A VACUUM TO CLEAN UP ASHES, BE SURE THE ASHES ARE ENTIRELY COOLED. USING
A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM.
NEVER OPERATE YOUR APPLIANCE WITH THE GRATE COVER REMOVED.
FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING, ASH PLUG OR ASH WELL DOOR
WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE.
!
WARNING
84.1
When wood is burned slowly, it produces tar and other organic vapours which combine with expelled moisture
to form creosote. These vapours condense in the relatively cooler chimney fl ue of a slow burning fi re and when
ignited, make an extremely hot fi re. So, the smoke pipe and chimney should be inspected monthly during the
heating season to determine if a buildup has occurred. If creosote has accumulated it should be removed to
reduce the risk of a chimney fi re.